RE-2 Residential Telephone Entry System With Built-in Wireless Receiver Installation, Programming, and Operation Instructions (760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.
CONTENTS PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . .1 INSTALLATION INFORMATION . . . . . . . . . . . . . . . . . . . . 2 COMPONENT LOCATIONS . . . . . . . . . . . . . . . . . . . . . . . . 3 WIRING DIAGRAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ENTRY SYSTEM MOUNTING . . . . . . . . . . . . . . . . . . . . . . 5 TELEPHONE WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 TELEPHONE WIRING OPTIONS . . . . . . . . . . . . . . . . . . . .
PRODUCT DESCRIPTION Linear’s RE-2 Telephone Entry System is designed for residential or light commercial access control applications. The speakerphone, keypad, radio receiver, and optional video camera are housed in a rugged enclosure that can be mounted to a pedestal, bolted directly to a wall, or mounted recessed in a wall with the optional trim ring. The die-cast keypad keys have bright, easy-to-read graphics and are lit with overhead lights.
INSTALLATION INFORMATION Before beginning installation, please review the entire instructions and become familiar with the system’s operation, wiring, and programmable options. System Location For pedestrian door or gate installations, mount the Entry System on a rigid wall near the controlled door. Avoid mounting the unit in a location where regular mechanical shock will occur due to a slamming door or spring loaded pedestrian gate.
COMPONENT LOCATIONS 5 2 1 3 15 20 19 18 16 8 6 4 17 7 14 12 13 10 11 9 1 HELP BUTTON Pressing this button causes the system to play the help message to instruct the visitor on system use. 11 2 CALL BUTTON Pressing this button causes the system to call the residence telephones with a distinctive ring signal. 12 STATUS INDICATORS Six indicators light to display system power, radio, and modem status. 3 OPTIONAL COLOR CCTV CAMERA Location for the optional Model CCM-2 color CCTV camera.
WIRING DIAGRAM RELAY #1 RELAY #2 N.C. COM N.O. N.C. N.O.
ENTRY SYSTEM MOUNTING Pedestal Mounting The RE-2 Entry System can be mounted with the Model GNC-1 (curb mount) or Model GNB-1 (burial mount) gooseneck pedestals. 1. Open the RE-2 case by removing the four security screws with the wrench provided (see Figure 1). 2. Use four security bolts and locking nuts to secure the backplate to the pedestal (see Figure 2). Wall Mounting The RE-2 Entry System can be mounted directly to a wall or flat surface. 1.
TELEPHONE WIRING OPTIONS TELEPHONE WIRING The RE-2 connects between the incoming telephone line of the residence and local telephone sets. Telephone Bypass Module The RE-2’s Telephone Bypass Module provides a switch to remove the RE-2 from the telephone line and re-connect the local telephones to the telephone system. ALL TELEPHONE WIRING FOR THE RE-2 MUST PASS THROUGH THE BYPASS MODULE.
MULTIPLE UNIT INSTALLATIONS Any of the four basic operation modes (Shared Line, Dedicated Line, Intercom, and Ring Down) may be used with multiple RE-2s. The telephone line wiring is “daisy chained” (the telephone line routes through one unit to the next) as shown below. Always connect the telephone line + to TIP, and - to RING. The Telephone Bypass Module only performs the bypass function in the Shared Line Mode, but it will provide extra electrical surge protection in all modes.
Door or Pedestrian Gate Control CONTROL WIRING Gate Control 1. Route two wires between the gate and the RE-2. Connect the gate operator’s OPEN terminals to the RE-2 Relay #1 COM & N.O. terminals. ✦ NOTE: For operator wiring specifics, refer to the gate operator’s wiring diagram. 2. If an access keyswitch is required refer to the Optional Keyswitch section of this manual for details on keyswitch wiring and installation. 3.
POWER, BATTERY, & GROUND WIRING TRANSFORMER Power Wiring ✦ NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS COMPLETE. 1. Route two wires between the RE-2 and the power transformer. • For power wire runs up to 100 feet, use 18 AWG, THHN 600-volt insulated wire. • For power wire runs up to 200 feet, use 16 AWG, THHN 600-volt insulated wire. 2. Connect the wires to the transformer. Connect the other end of the wires to the two RE-2 TRANSFORMER terminals.
OPTIONAL REMOTE KEYPAD OPTIONAL KEYSWITCH The optional Model AM-KP remote keypad can be used with the RE-2 entry system. A typical application for the remote keypad would be to control a second door or gate. Entry codes are the only method of access allowed at a remote keypad. The default system setting will cause the remote keypad to activate Relay #2. 1. Mount the AM-KP keypad onto a pedestal or to a wall. 2. Route 6-conductor cable from the RE-2 to the AM-KP.
OPTIONAL COLOR CCTV CAMERA Linear’s Model CCM-2 CCTV camera can be installed inside the RE-2 Entry System. The camera provides a video signal for viewing the area in front of the entry system. The CAMERA connector is used to connect the camera to the RE-2. The 4-conductor cable routes power to, and video from the camera. The VIDEO OUT connector is the camera output for connection to a video cable with a Type “BNC” connector. Up to 400 feet of 75-ohm RG-59 video cable can be used.
PROGRAMMING ACCESS The RE-2 can be programmed locally or remotely. The system’s built-in programming software can be accessed on-site or off-site using a computer with any Internet browser. Without a computer, the RE-2 can be programmed from its main keypad, from any local TouchTone® telephone connected to the same line, or from any remote TouchTone® telephone by calling the unit. To guide you through the programming, the RE-2’s voice synthesizer will announce programming prompts over the telephone.
SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION 1. FROM CONTROL PANEL SELECT "NETWORK CONNECTIONS" THEN SELECT "NEW CONNECTION WIZARD" 2. THE NEW CONNECTION WIZARD WILL START CLICK "NEXT" 4. NEW CONNECTION WIZARD - "GETTING READY" SELECT "SET UP MY CONNECTION MANUALLY" 5. NEW CONNECTION WIZARD - "INTERNET CONNECTION" SELECT "CONNECT USING DIAL UP MODEM" 7. NEW CONNECTION WIZARD - "PHONE NUMBER TO DIAL" FOR A REMOTE CONNECTION, ENTER THE PHONE NUMBER OF THE RE-2'S PHONE LINE.
CONNECTING TO THE RE-2 1. DOUBLE-CLICK ON DESKTOP ICON TO LAUNCH THE CONNECTION WINDOW 6. AFTER CONNECTING, SWITCH TO YOUR MICROSOFT INTERNET EXPLORER BROWSER SOFTWARE AND ENTER THIS ADDRESS: http://192.168.20.10/re1.html 2. CLICK "DIAL" TO START THE CONNECTION 3. THE MODEM WILL DIAL THE NUMBER 4. ONLY WHEN CONNECTING REMOTELY, AFTER THREE RINGS, CLICK "CANCEL", WAIT 10 SECONDS THEN REPEAT STEPS 1-3. THE RE-2 WILL ANSWER THE PHONE ON THE SECOND CALL ATTEMPT 5.
PROGRAMMING REFERENCE PROGRAMMING CONTROL USAGE KEYSTROKES ENTER PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ###MASTER CODE# ESCAPE/CANCEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . * EXIT PROGRAMMING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99# PROGRAM POSITION NUMBERS (PPN) ENTRY CODE LENGTH . . . . . . . . . . . . . . . . . . .
BASIC SYSTEM PROGRAMMING ENTRY CODE PROGRAMMING Entering Programming Mode Setting the Entry Code Length The 6-digit Master Programming Code (default = 123456) is used to enter Programming Mode from a local or remote telephone or the keypad. Master Code Press: Master Code = the current 6-digit Master Programming Code Exiting Programming Mode Press: ✦ NOTE: The RE-2 will automatically exit Programming Mode after five minutes of programming inactivity.
TRANSMITTER PROGRAMMING TELEPHONE PROGRAMMING Adding Transmitters Maximum Number of Visitor Rings Up to four groups of transmitters can be assigned common access privileges sharing the same one or two time zones. Up to 100 transmitters total in all groups combined can be used in each RE-2 system.
Call Forwarding Feature Default: OFF The call forwarding feature will allow a visitor to contact the resident at the programmed telephone number instead of through the local telephone line. The feature can be set to be active during a selected Time Zone or at all times. The telephone number programmed can contain an extension number and an optional time delay before dialing the extension.
Keypad Beeps On/Off Model MGT Gate Edge Transmitter Setup Linear’s Model MGT Gate Edge Transmitter can be used with the RE-2 for obstacle detection. When the gate edge sensor triggers the MGT transmitter, the RE-2 can be programmed to activate Relay #2 which would in turn, activate the obstacle input of the gate operator.
SYSTEM ADJUSTMENTS The RE-2 Entry System audio levels can be adjusted to suit the installation requirements. If required, make these adjustments after programming, but before closing and securing the RE-2 case. Speakerphone Volume The SPEAKERPHONE VOLUME adjustment controls the audio level that the RE-2 speaker produces during communications between the visitor and the resident. ✦ NOTE: Adjusting the speaker volume too high will cause the speech to cut-out as the system switches from talk to listen. 1.
Residence Telephone Commands RE-2 OPERATION Requesting Access with an Entry Code • Visitors have up to 40 seconds to key in their entry code. • Up to eight seconds are allowed between each keystroke. • The system can be controlled by the resident without a call from a visitor by using any telephone connected to the local line. • To activate and latch Relay #1 press • All digits of the entry code must be entered. Example: If the code is 0042, the user must enter “0 0 4 2”.
RESIDENT PROGRAMMING QUICK REFERENCE Some of the programming PPN’s may be commonly used by the resident. Following are quick references to the keystrokes required. Maximum Number of Visitor Rings Press: Rings Rings = 1-15 Rings maximum ✦ NOTE: The “###” is the default command prefix. The following example assumes that the default has not been changed.
SPECIFICATIONS MECHANICAL Case dimensions: ELECTRICAL Voltage: Current: Backup Battery: Backup Battery Current: TROUBLESHOOTING System will not go into programming mode 10” W x 6-1/8” H x 4” D 1. Wrong master code entered.
PROGRAMMING WORKSHEET TIME ZONES ACTIVE DAYS TIME ZONE SUN MON TUE WED THU START TIME FRI SAT HOLIDAYS HOUR END TIME MINUTE AM/PM HOUR MINUTE AM/PM 1 2 3 4 5 6 7 HOLIDAYS HOLIDAY NAME SYSTEM PROGRAMMING MONTH DAY FEATURE ENTRY CODE LENGTH 1 2 3 4 5 6 7 8 9 10 10 MASTER CODE CALL FORWARDING NUMBER ALTERNATE TELEPHONE NUMBER 1 ALTERNATE TELEPHONE NUMBER 2 ALTERNATE TELEPHONE NUMBER 3 24 PPN DEFAULT 1 4 TX LEFT BUTTON 8 RELAY #1 TX RIGHT BUTTON 8 RELAY #2 TX TOP BUTTON 8
ENTRY CODE RELAY # TIME ZONE ENTRY CODE RELAY # __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __
LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twenty-four (24) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any.