H3 Datasheet(Revision1.2) Copyright© 2015 Allwinner Technology Co.,Ltd.All Rights Reserved. Page 154
1: Enable
3
R/W
0x0
ETXIE
Enable EMAC Transmit Clock Invertor.
0: Disable
1: Enable
2
R/W
0x0
EPIT
EMAC PHY Interface Type
0: MII
1: RGMII
1:0
R/W
0x0
ETCS.
EMAC Transmit Clock Source
00: Transmit clock source for MII
01: External transmit clock source for GMII and RGMII
10: Internal transmit clock source for GMII and RGMII
11: Reserved