H3 Datasheet(Revision1.2) Copyright© 2015 Allwinner Technology Co.,Ltd.All Rights Reserved. Page 331
18:16
R/W
0x7
PE4_SELECT
000:Input 001:Output
010: CSI_D0 011:TS_D0
100: Reserved 101:Reserved
110:Reserved 111:IO Disable
15
/
/
/
14:12
R/W
0x7
PE3_SELECT
000:Input 001:Output
010:CSI_VSYNC 011:TS_DVLD
100: Reserved 101:Reserved
110:Reserved 111:IO Disable
11
/
/
/
10:8
R/W
0x7
PE2_SELECT
000:Input 001:Output
010:CSI_HSYNC 011:TS_SYNC
100:Reserved 101:Reserved
110:Reserved 111:IO Disable
7
/
/
/
6:4
R/W
0x7
PE1_SELECT
000:Input 001:Output
010:CSI_MCLK 011:TS_ERR
100:Reserved 101:Reserved
110:Reserved 111:IO Disable
3
/
/
/
2:0
R/W
0x7
PE0_SELECT
000:Input 001:Output
010:CSI_PCLK 011:TS_CLK
100:Reserved 101:Reserved
110:Reserved 111:IO Disable
4.22.2.29. PE Configure Register 1 (Default Value: 0x77777777)
Offset: 0x94
Register Name: PE_CFG1_REG
Bit
R/W
Default/Hex
Description
31
/
/
/
30:28
R/W
0x7
PE15_SELECT
000:Input 001:Output
010: Reserved 011: Reserved
100: Reserved 101:Reserved
110:Reserved 111:IO Disable
27
/
/
/
26:24
R/W
0x7
PE14_SELECT
000:Input 001:Output
010: Reserved 011: Reserved
confidential