Owners manual
System
H3 Datasheet(Revision1.2) Copyright© 2015 Allwinner Technology Co.,Ltd.All Rights Reserved. Page 338
100:Reserved 101:Reserved
110:PG_EINT1 111:IO Disable
3
/
/
/
2:0
R/W
0x7
PG0_SELECT
000:Input 001:Output
010:SDC1_CLK 011:Reserved
100:Reserved 101:Reserved
110:PG_EINT0 111:IO Disable
4.22.2.47. PG Configure Register 1 (Default Value: 0x00777777)
Offset: 0xDC
Register Name: PG_CFG1_REG
Bit
R/W
Default/Hex
Description
31:23
/
/
/
22:20
R/W
0x7
PG13_SELECT
000:Input 001:Output
010: PCM1_DIN 011: Reserved
100:Reserved 101:Reserved
110:PG_EINT13 111:IO Disable
19
/
/
/
18:16
R/W
0x7
PG12_SELECT
000:Input 001:Output
010: PCM1_DOUT 011: Reserved
100:Reserved 101:Reserved
110:PG_EINT12 111:IO Disable
15
/
/
/
14:12
R/W
0x7
PG11_SELECT
000:Input 001:Output
010: PCM1_CLK 011: Reserved
100:Reserved 101:Reserved
110:PG_EINT11 111:IO Disable
11
/
/
/
10:8
R/W
0x7
PG10_SELECT
000:Input 001:Output
010: PCM1_CLK 011: Reserved
100:Reserved 101:Reserved
110:PG_EINT10 111:IO Disable
7
/
/
/
6:4
R/W
0x7
PG9_SELECT
000:Input 001:Output
010:UART1_CTS 011: Reserved
100:Reserved 101:Reserved
110:PG_EINT9 111:IO Disable
3
/
/
/