H3 Datasheet(Revision1.2) Copyright© 2015 Allwinner Technology Co.,Ltd.All Rights Reserved. Page 463
This register can be accessed in byte, half-word or word unit by AHB. In byte
accessing method, if there are data in RXFIFO, the top word is returned and
the RXFIFO depth is decreased by 1. In half-word accessing method, two SPI
bursts are returned and the RXFIFO depth is decrease by 2. In word
accessing method, the four SPI bursts are returned and the RXFIFO depth is
decreased by 4.
Note: This address is read-only if RF_TEST is ‘0’, and if RF_TEST is set to ‘1’,
this address is readable and writable to test the RX FIFO through the AHB
bus.
confidential