Owners manual
Electrical Characteristics
H3 Datasheet(Revision1.2) Copyright© 2015 Allwinner Technology Co.,Ltd.All Rights Reserved. Page 611
9.5. Power up and Power down Sequence
The power rails for H3 is supported by discrete ICs. For the detailed information about discrete ICs, please see to their
application notes.Figure 9-1 shows an example of the power-up sequence for H3 device, it contains
5V,3.3V,2.5V,1.8V,1.5V,1.25V,1.2V power rails.
During the entire power-up sequence, the Reset pin must be held low until all power domains are stable.After all power
domains are on, the Reset signal is pulled high about 260ms later.
Figure 9-1. Power On Sequence
Table 9-6. Power-up Timer Parameter
Parameter
Symbol
Min
Typ
Max
Unit
VCC-5V Ramp Up Rate
T1
0.1
10
20
ms
The delay startup time
between VCC-5V and
T2
0
2
10
ms
confidential