Owner's Manual

Table Of Contents
48
Global Settings
Select whether to enable or disable the LLDP feature on the Switch. Next, enter the Transmission
Interval, Holdtime Multiplier, Reinitialization Delay parameter, and the Transmit Delay parameter.
When finished, click Apply to update the system settings.
State
Select Enabled or Disabled to activate LLDP for the Switch.
Transmission
Interval
Enter the interval at which LLDP advertisement updates are sent.
The default value is 30. The range is from 5 to 32768.
Holdtime Multiplier
Enter the amount of time that LLDP packets are held before packets
are discarded and measured in multiples of the Advertised Interval.
The default is 4. The range is from 2 to 10.
Reinitialization
Delay
Enter the amount of time of delay before reinitializing LLDP. The
default is 2. The range is from 1 to 10.
Transmit Delay
Enter the amount of time that passes between successive LLDP
frame transmissions. The default is 2 seconds. The range is from 1 to
8191 seconds.