CALIBRATION SETUP 3
Calibration #: (LB) C - U - L
FlightConnect
The active calibration of 16 possible calibrations. The elds shown
on the Calibration Setup 3 screen represent the values of the
Calibration # shown. Any edits made to the elds are attributed to
the Calibration # shown. FlightConnect only uses Calibration #1.
Linearization Mode: (LB) C
Disables and enables multi-point calibration.
Setup disables multi-point calibration during normal fuelings. Used when
proving and setting multi-point calibrations.
Applied enables multi-point calibration.
Linearization Prover Qty: (TB) C
The metered volume of the prover after a calibration fueling. When the prover volume is entered, the LCR 600 will
prompt you to select a linearization point number and a ow rate. After these values are entered, the LCR 600 will
assign the error accordingly.
BEGIN CALIBRATION DELIVERY
Starts a calibration fueling.
Point #: (TB) C
The elds under Point #: are used to calibrate the owmeter/register at up to
10 different ow rates for each product type/calibration.
Flow Rate: (TB) C
The ow rate at which the calibration point was measured.
Percent Error: (TB) C
This eld contains the percent difference between the register volume and the prover volume.
Percent Error = [(Prover Qty. - Meter Qty.) ÷ Prover Qty.] x 100
Next/Previous Screen
GALLONS
APPLIED
50.12
Flow Rate
88.00
11.00
38.00
22.00
30.00
63.00
75.00
0.00
0.00
0.00
Percent Error
-0.030
-0.108
-0.138
-0.171
-0.149
-0.084
-0.055
0.000
0.000
0.000
Calibration #: 1
Linearization Mode:
Linearization Prover Qty:
BEGIN CALIBRATION DELIVERY
Point #
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
CALIBRATION SETUP
3
SETUP - CALIBRATION SETUP
L - Locked
U - Unlocked
C - Weights & Measures Calibration
P - Stop/Pause
F - Factory
Security Clearance
Single Point or Multi-Point Calibration
The LCR 600 provides two means of calibration, single point or multi-point calibration. A “point” corresponds to a
particular ow rate along the owmeter’s accuracy curve. Single point calibration adjusts one point along the accuracy
curve to zero percent error—typically the standard ow rate of a normal fueling. Multi-point calibration zeroes the
percent error at multiple ow rates in order to atten out the accuracy curve across the owmeter’s range of ow
rates. Multi-point calibration is ideal for applications in which fuelings are made at many different ow rates, while
single point calibration is appropriate for applications where a high ow rate is typical for most fuelings.
Single Point Calibration Accuracy Curve Multi-point Calibration Accuracy Curve
Single Point and Multi-Point Calibration Accuracy Curves
TB - Text Box
LB - List Box
Field Type