Setup & Op User guide
18
INTRODUCTION - SECURITY
LOCKED
An owner/ofce security setting that limits the access of
drivers to a small number of delivery, system, and POS
elds.
To lock the LCR 600
1. Select the Security screen from the Conguration Menu.
2. Move the pointer to User Key: eld and press the
EntEr button.
3. Enter an alphanumeric password in the eld edit box and
press the EntEr button
4. Move the pointer to the Security: eld and press the
EntEr button.
5. Move the pointer to Locked in the list box and press
the EntEr button.
UNLOCKED
An owner/ofce security setting that allows drivers
access to a large number delivery, system, and POS
elds.
To unlock the LCR 600
1. Select the Security screen from the Conguration Menu.
2. Move the pointer to User Key: eld and press the
EntEr button.
3. Enter the same alphanumeric password that was
entered when the LCR 600 was locked. The value of the
Security: eld will change to UNLOCKED.
Throughout this manual, the security levels that
allow access to a each LCR 600 eld is included
with the eld denition. The abbreviation for
each security level is as follows:
L - Locked
U - Unlocked
C - Weights & Measures Calibration
P - Stop/Pause
F - Factory
Six O’clock Calibration Position
WEIGHTS & MEASURES CALIBRATION
The Weights & Measures Calibration security setting
allows access to all elds and functions necessary
for Weights & Measures approval and the complete
conguration of the LCR 600 for service.
To enter the Weights & Measures Calibration mode
1. Remove the faceplate around the red selector switch.
If the LCR 600 was Weights & Measures approved
beforehand, you will need to remove the lead seal and
wire threaded through the switchplate screws.
2. Turn the selector switch to the six o’clock position.
STOP/PAUSE
During deliveries, there are certain elds that may
be edited if the selector switch is turned to the STOP
(pause) position, for example, preset and miscellaneous
charges elds. After editing a eld, the delivery can be
continued by turning the selector switch back to RUN.
FACTORY
A security setting restricted to LC factory personnel.
Levels of Security
Many elds listed in the LCR 600 screens are accessible only while certain security levels are in place. The security
levels provide the safeguards essential for Weights & Measures approval, and they give owners and operators a
means of restricting drivers to certain functions. There are ve levels of security on the LCR 600: Locked, Unlocked,
Weights & Measures Calibration, Stop/Pause, and Factory.
When a delivery is active LCR 600 elds are not editable.
Active Delivery Status