SYSTEM SETUP
SYSTEM SETUP 1
Meter ID: (FE) C
The identication number of the meter the LCR 600 is
mounted on. If the LCR 600 is installed in a multiple-meter
system, it is important this number be unique. The number is
printed on the calibration/diagnostic ticket. LC recommends
entering the meter’s serial number to ensure identication.
LCP Node Address: (FE) C - U
Node address used by a host application, like the DMS i1000,
to communicate with the LCR 600.
Unit of Measure: (LB) C
The unit of ow measurement.
Gallons • Litres • Cubic M • Lbs (pounds) • Kgs • Barrels • Other
Decimal Digit: (LB) C
The decimal place of volume measurements shown on the display and printed tickets.
Hundredths • Tenths • Whole
Residual Processing: (LB) C
The treatment of excess decimal places when displaying and printing volume measurements
Round according to one half of the least signicant digit
Truncate disregards the excess digits
Flow Rate Base: (LB) C
The time unit of the measured ow rate.
Per Second • Per Minute • Per Hour
Flow Direction: (LB) C
The direction of ow through the meter. If the LCR 600 is counting in reverse (decreasing numbers), select the
opposite Flow Direction.
<− • −>
Printer: (LB) C
The type of printer connected to the LCR 600.
EPSON NewFontB EPSON 200 Roll and EPSON 220 Roll
EPSON NewFontA EPSON TM-T88iii
EPSON OldFontA EPSON 290 Slip and EPSON 295 Slip
EPSON OldFontB EPSON 300 Roll
OKIDATA ML184T OKIDATA ML184T
BLASTER Cognitive Solutions Thermal Printer.
L - Locked
U - Unlocked
C - Weights & Measures Calibration
P - Stop/Pause
F - Factory
Security Clearance
FE - Field Edit Box
LB - List Box
Field Type