Setup & Op User guide

25
SYSTEM SETUP
Ticket Required: (LB) C
Determines if the printer is required to be online and ready to print in order to start a delivery. Most Weights &
Measures governed truck applications require a ticket.
Yes deliveries disabled unless a ticket is in the printer, the previous delivery ticket is completed, and the printer is operational.
No
deliveries enabled without printer. Tickets will print if the printer is online and has paper.
∆P Shutdown Value: (FE) C
The differential pressure amount that will shut down an active delivery. This feature pertains to meter systems with a
differential pressure transducer and requires a shutdown device. If the value is set to 0, the feature is disabled. 0 to
59.9 range.
SYSTEM SETUP 2
Temperature: (FE) C
The current temperature reading of the RTD temperature
probe. To calibrate, simply enter the Weights & Measures
thermometer reading. If the LCR 600 does not have an ETVC
Kit, this eld will read “--”.
Temperature Offset: (FE) C
The difference between the ofcial Weights & Measures
reading and the LCR 600 RTD reading. The offset is
automatically calculated if an entry is made in the previous
eld. ±0.3°C or ±0.54°F range.
Temperature Unit of Measure: (LB) C
The unit of temperature measured, displayed, and printed.
Deg. C
Deg. F
RTD Slope: F
Factory calibration setting only.
RTD Offset: F
Factory calibration setting only.
Last Calibration Date: Display only
The date and time of the last calibration.
Calibration #: Display only
The number of times the calibration position has been entered. For Weights & Measures use only.
Calibration Event #: Display only
The number of times the calibration has been changed. For Weights & Measures use only. Calibration events
include the following: Pulses Per Unit (k-Factor) • Linearization Flow Rate • Linearization Percent Error • Activating
Linearization
Conguration Event #: Display only
The number of times the conguration has been changed. For Weights & Measures use only. Conguration
events include the following: Sale Number • Gross Totalizer • Net Totalizer • Product Type • Compensation Type
• Compensation Parameter • Base Temperature • Auxiliary Multiplier • Auxiliary Unit of Measure • S1 Close •
Temperature Offset • Temperature Scale • Quantity Unit of Measure • Decimal Setting • Flow Rate Unit of Measure •
Printer Type • Ticket Required Flag • Flow Direction • Meter ID • Ticket Number • Residual Processing • Print Gross
and Parameter Flag • Print Volume Corrected Message Flag
Delivery Screen: (FE) C
The format of the active delivery screen, four predened. The Detailed POS is only available LCR 600 POS
upgrade. See the pg. 26 for illustrations.
User Dened • Detailed Pump & Print • Volume and Preset • Aviation • Detailed POS