Setup & Op User guide

32
CALIBRATION SETUP 1
Calibration #: (LB) C - U - L
The active calibration of four possible calibrations (16
calibrations possible with POS upgrade). The elds shown
on the Calibration Setup 1 screen represent the values of
the Calibration # shown. Any edits made to the elds are
attributed to the calibration # shown.
Calibration Code: (FE) C - U
The code assigned to the active calibration. This code can
be used to correspond with an ofce code.
Calibration Name: (FE) C - U
The text designation of the active calibration.
Calibration Type: (LB) C
The type of product of the active calibration.
Ammonia • Aviation • Distillate • Gasoline • Methanol • LPG • Lube Oil • blank
Linearization Mode: (LB) C
Disables and enables single and multi-point calibration.
Setup allows the setting of single and multi-point calibration. Disables single and multi-point calibration settings in deliveries.
Applied enables multi-point calibration settings in delivery .
Pulses/Unit <k-Factor>: (FE) C
The number of pulse edges per unit of measure. Applies only to gross volume. This number scales the prover
quantity. A unit of 20.0000 is entered on all factory shipments. Changing the k-factor moves the entire meter accuracy
curve either up or down.
Prover Quantity: (FE) C
The metered volume of the prover after a calibration delivery. When the prover volume is entered, the LCR 600
adjusts the k-factor to calibrate the pulses/unit. See calibration instructions.
BEGIN CALIBRATION DELIVERY
Starts a calibration delivery.
S1 Close: (FE) C
The point during a preset delivery when the valve switches from full ow to a dwell ow. The value is set according
volume units remaining in the delivery. 0 to 500 range.
Net Totalizer: C
Net volume delivered by the LCR 600. In the calibration position, the eld can be set to any positive value. The value
resets after a clear all.
Gross Totalizer: C
Gross volume delivered by the LCR 600. In the calibration position, the eld can be set to any positive value. The
value resets after a clear all.
CALIBRATION SETUP
L - Locked
U - Unlocked
C - Weights & Measures Calibration
P - Stop/Pause
F - Factory
Security Clearance
FE - Field Edit Box
LB - List Box
Field Type