Setup & Op User guide
50
OPERATION - DELIVERY SETUP
DELIVERY SETUP 2
Calibration details - Display Only
The calibration number, calibration code, calibration name
and calibration type of the active calibration
Auxiliary 1 Output: (LB) U
Determines when to activate the Auxiliary 1 component.
Common Auxiliary 1 components are pump controls, additive
injectors, and alarms. The value of this eld is unique to each
product. The options include:
Off
On
On During Delivery
Monitor Flow Rate activates Auxiliary 1 at the beginning of the delivery and deactivates at 40 units/time owrate
Toggle Flow Rate activates Auxiliary 1 at owrate designated in the Toggle Flow Rate eld
Auxiliary 2 Output: (LB) U
Determines when to activate the Auxiliary 2 component. Common Auxiliary 2 components are pump controls, additive
injectors, and alarms. The value of this eld is unique to each product. The options include:
Off
On
On During Delivery
Flow Direction activates Auxiliary 2 according to the Flow Direction eld on the System Setup 1 screen
Toggle Flow Rate: (FE) U
The ow rate value at which Auxiliary 1 activates in the Toggle Flow Rate: mode. Auxiliary 1 remains activated
above the set ow rate value and deactivates when the ow rate falls below the value. A common output is an air
operated valve (AOV) on the pump. When the ow rate value is attained, the AOV is activated switching the pump
from low bypass pressure mode to full ow fuel mode (high bypass pressure). When the ow rate falls below the
set value, the AOV deactivates and the pump returns to low ow. Another possible output is the engine throttle—to
increase and decrease the RPM of the pump shaft. In applications such as these, the ow rate value in this eld
should be below the low ow rate with a fully open nozzle or the output will never turn on. Another application of this
eld is to set the value as a maximum ow rate at which a valve should be closed. On fuel delivery trucks, ow valves
often activate an internal switch at approximately 18 GPM (68 LPM). The value of this eld is unique to each product.
Ticket Header Text: (FE) U (Lines 11 and 12 are Weights & Measures protected )
Supplies 10 lines where you can enter text for the ticket header. Every delivery ticket printed by the LCR 600 will print
this text at the top of every ticket. Lines 11 and 12 must be edited in General Setup 2 while in the calibration position.
DELIVERY SETUP 3
Calibration details - Display Only
The calibration number, calibration code, calibration name
and calibration type of the active calibration.
Shift Start: Display Only
Date and time when the active shift started.
Deliveries: Display Only
Number of deliveries for the active shift.
Shift Net: Display Only
Net volume delivered during the active shift.
Shift Gross: Display Only
Gross volume delivered during the active shift.
FE - Field Edit Box
LB - List Box
Field Type