Appendix A - Compensation Types & Parameters
The table below shows the supported methods of calculating the Volume Correction Factor (VCF). The method is
independently selectable for each product in Product Calibration. The table below shows the valid temperature
ranges for each table. The hold temperature, T
hold
, is the temperature that VCF is held at for temperatures < T
hold
and
> T
min
. This is done to allow compensation in very cold environments where further extrapolation of equations is not
allowed.
General
Linear Linear 0 to 0.003 ºC 15 -90 N/A +100
General
Linear Linear 0 to 0.005 ºF 60 -130 N/A +212
LPG
USA
LPG
Europe &
Canada
Refined
Petroleum
Products
Europe &
Canada
Refined
Petroleum
Products
USA
General
API Table 54C Coefficient
0.000486 to
0.001674
ºC 15 -50 -40 +95
Lube Oil
Europe &
Canada
Ammonia
Canada
+40
-50 -40 +95
15 -30 -30NH
3
N/A N/A
60
Density
kg/m3
API Table 54D 800 to 1164 ºC 15
ºC
+95
-50 -40 +200API Table 6B API Gravity 0 to 85 ºF
API Table 54B 653.0 to 1075.0 ºC 15 -50 -40
0.5 to 0.600 ºC 15 -46 -46 +60
T
m ax
API Table 24
Specific
Gravity
0.5 to 0.550 ºF 60 -50 -50 +140
Scale
ºC or ºF
Density
kg/m3
Density
kg/L
T
base
T
m in
T
hold
Product VCF Type
Parameter
Coefficient
Range
API Table 54