Install E3650-E3651 Series Owner manual
Pull-down resistors of 300 Ω needs to be connected between
CHAN B and GND, and CHAN A and GND.
To operate a single channel pulser, a jumper is required between
pins 2 and 3 on J4.
J8-38
37 GND N/A Pulser Signal GND
36
35
34
33 In 4 N/A Pulse Output
32
31 +Vo Red +V Input
J8-38
37 GND White Pulser Signal GND
36
35
34 In 3 Orange Channel B Output
33 In 4 Black Channel A Output
32
31 +Vo Red +V Input
J12-45 +Vo N/A
44
Out 1
Aux. 1
N/A Pump or Aux. Control
43
Out 2
Aux. 2
N/A Flow Direction
42 Out 3 N/A
Pulse Input for Aux.
System
41 GND N/A
40 Out 4 N/A Display Input
39 Out 5 N/A Display Input
J13-19 Earth Green
Solenoid 2 Case
Ground
18 Out 6 Black or Red Solenoid 2
17 +Vo Black or Red Solenoid 2
16 Earth Green
Solenoid 1 Case
Ground
15 Out 7 Black or Red Solenoid 1
14 +Vo Black or Red Solenoid 1
J14-23 RTD-D Red RTD
22 RTD-S Red RTD
21 RTD+D White RTD
20 RTD+S White RTD
J15-56 +Vo Red Optical Sensor
55 In 5 White Optical Sensor
54 GND Black Optical Sensor
53 Out 8 Black Solenoid 3
52 +Vo Red Solenoid 3
37