APPENDIX B: SCAMP FUNCTION TABLE
“0/1” Jumper Set in Position “0”
Function
Switch
Setting
Displayed Value
0 Gross k-Factor (gross metering mode).
1 Linear F compensation parameter and current temperature in degrees Fahrenheit.
2 Linear C compensation parameter and current temperature in degrees Celsius.
3 Table 24 compensation parameter and current temperature in degrees Fahrenheit.
4 Table 54 compensation parameter and current temperature in degrees Celsius.
5 Table 54A compensation parameter and current temperature in degrees Celsius.
6 Table 54B compensation parameter and current temperature in degrees Celsius.
7 Table 54C compensation parameter and current temperature in degrees Celsius.
8 Table 54D compensation parameter and current temperature in degrees Celsius.
9 Table 6B compensation parameter and current temperature in degrees Fahrenheit.
A Current temperature in degrees Celsius. (NH
3
compensation is active)
B Seven segment display test.
C Temperature Offset Adjustment and Current Adjusted Temperature. The
temperature is displayed in Celsius or Fahrenheit depending on the temperature
scale selected.
D Serial Programming Mode (consult factory)
E Last recorded disabling error number.
F Electromechanical pulse output scale factor.
“0/1” Jumper Set in Position “1”
Function
Switch
Setting
Displayed Value
0 Flow rate and percent error for linearization point # 0.
1 Flow rate and percent error for linearization point # 1.
2 Flow rate and percent error for linearization point # 2.
3 Flow rate and percent error for linearization point # 3.
4 Flow rate and percent error for linearization point # 4.
5 Flow rate and percent error for linearization point # 5.
6 Flow rate and percent error for linearization point # 6.
7 Flow rate and percent error for linearization point # 7 .
8 Flow rate and percent error for linearization point # 8.
9 Flow rate and percent error for linearization point # 9.
A Flow rate and percent error for linearization point # A.
B Flow rate and percent error for linearization point # B.
C Flow rate and percent error for linearization point # C.
D Flow rate and percent error for linearization point # D.
E Flow rate and percent error for linearization point # E.
F Flow rate and percent error for linearization point # F.