SDS

LN-3000 LIQUID NAILS FUZE IT MAX TAN
Product name
1
Product code
Date of issue
Version
00437451
16 March 2020
Section 6. Accidental release measures
Section 7. Handling and storage
Advice on general
occupational hygiene
Conditions for safe storage,
including any
incompatibilities
Eating, drinking and smoking should be prohibited in areas where this material is
handled, stored and processed. Workers should wash hands and face before eating,
drinking and smoking. Remove contaminated clothing and protective equipment before
entering eating areas. See also Section 8 for additional information on hygiene
measures.
Do not store above the following temperature: 50°C (122°F). Store in accordance with
local regulations. Store in original container protected from direct sunlight in a dry, cool
and well-ventilated area, away from incompatible materials (see Section 10) and food
and drink. Keep container tightly closed and sealed until ready for use. Containers that
have been opened must be carefully resealed and kept upright to prevent leakage. Do
not store in unlabeled containers. Use appropriate containment to avoid environmental
contamination.
:
:
Protective measures
Put on appropriate personal protective equipment (see Section 8). Persons with a
history of skin sensitization problems should not be employed in any process in which
this product is used. Avoid exposure - obtain special instructions before use. Do not
handle until all safety precautions have been read and understood. Do not get in eyes
or on skin or clothing. Do not ingest. Use only with adequate ventilation. Wear
appropriate respirator when ventilation is inadequate. Keep in the original container or
an approved alternative made from a compatible material, kept tightly closed when not
in use. Empty containers retain product residue and can be hazardous. Do not reuse
container.
:
Precautions for safe handling
Special precautions
:
Vapors may accumulate in low or confined areas or travel a considerable distance to a
source of ignition and flash back. Vapors are heavier than air and may spread along
floors. If this material is part of a multiple component system, read the Safety Data
Sheet(s) for the other component or components before blending as the resulting
mixture may have the hazards of all of its parts.
crystalline silica, respirable powder (<10 microns)
ACGIH TLV (United States, 3/2019).
TWA: 0.025 mg/m³ 8 hours. Form:
Respirable
OSHA PEL Z3 (United States, 6/2016).
TWA: 10 mg/m³ / (%SiO2+2) 8 hours. Form:
Respirable
TWA: 250 mppcf / (%SiO2+5) 8 hours. Form:
Respirable
OSHA PEL (United States, 5/2018).
TWA: 50 µg/m³ 8 hours. Form: Respirable
dust
amide wax
ACGIH TLV (United States).
TWA: 3 mg/m³ Form: Respirable dust
Section 8. Exposure controls/personal protection
Ingredient name
Exposure limits
Control parameters
Occupational exposure limits
United States
Page: 5/13