SDS

DIRECTIONS:
Preparation: Surfaces must be clean, dry and structurally sound.
1. Cut nozzle at a 45° angle to desired size.
2. Puncture inner seal with nail or wire.
Cabinets and counter tops: Apply a 1/4" bead to contact areas on the back of cabinets
or counter tops. Press firmly into place. Mechanical fasteners must also be used for
installing wall cabinets.
Materials to furring strips or studs: Apply zigzag 1/4" bead to each strip or stud to
be covered by panel. Position panel so edges meet at stud center; only severely warped
materials require finishing nails at top and bottom.
CLEAN-UP
Use mineral spirits or an adhesive remover.
DISPOSAL
Contains organic solvents which may cause adverse effects to the environment if disposed
of improperly. Place empty containers in normal refuse for disposal. Contact your sanitation
department or household hazardous waste coordinator for information concerning possible
re-use or disposal of unused solvent-containing adhesives and/or sealants.
EAD-C9
LIMITED WARRANTY
Macco warrants satisfaction with this product when handled and applied according to
label instructions. If this product is not as warranted, please call 1-800-634-0015 for
refund or product replacement details. This warranty excludes labor or the cost of labor
and is given as the exclusive warranty and remedy. No warranty of merchantability, fitness
for purpose or other warranty, express or implied, is made. Macco shall not be liable for
any special, incidental or consequential damages. Some states do not allow the exclusion
of incidental or consequential damages, so the limitations may not apply. This warranty
gives specific legal rights. You may also have other rights that vary from state to state.
NO. 99444/LN-901/LNP-901 0905 © 2004-2006 ICI Paints, all rights reserved Printed in the USA
Base: Synthetic rubber & resin
Type: Solvent
Color: Tan
Appearance: Smooth
Application Temperature:
40° to 100° F (5° to 38° C)
Service Temperature:
-20° to 140° F (-29° to 60° C)
Adhesion: Excellent
Consistency: Short buttery
Bridging Ability: Excellent
Extrudability: Easy
Shear Strength:
24 hours – 225 psi
48 hours – 300 psi
7 days – >425 psi
Durability: Excellent; 20 year life
Flexibility: Excellent
Water Resistance: Excellent
Exterior Weathering: Very good;
adhesive not recommended
for direct exposure to sunlight
Staining: May stain marble
Odor: Mild solvent
Working Time: 10 minutes
Weight Per Gallon: 9.4 pounds (1.12 kg/l)
Viscosity: 230,000 CPS
Volatiles: 35%
Solids: 65%
Flammability: Extremely flammable;
nonflammable when dry
Flash Point: 1°F (-17°C)
Coverage:
30 lineal ft. using 1/4" bead for 10 fl.oz.;
85 lineal ft. using 1/4" bead for 28 fl.oz.
Shelf Life: 12 months from date of purchase
Specifications: Exceeds ASTM C-557
MAX VOC: 401 GPL
LN-901/LNP-901
TECHNICAL INFORMATION
DANGER! EXTREMELY FLAMMABLE.
CAUSES EYE AND SKIN BURNS. HARMFUL OR FATAL IF SWALLOWED. HARMFUL IF INHALED.
MAY CAUSE CENTRAL NERVOUS SYSTEM EFFECTS, INCLUDING DIZZINESS, HEADACHE OR
NAUSEA. CAUSES RESPIRATORY TRACT IRRITATION. USE ONLY WITH ADEQUATE VENTILATION.
KEEP OUT OF THE REACH OF CHILDREN.
NOTICE: Reports have associated repeated and prolonged occupational overexposure to solvents with permanent
brain and nervous system damage. Intentional misuse by deliberately concentrating and inhaling the contents
may be harmful or fatal. Contains Crystalline Silica. If sanding, wear a dust mask to avoid breathing of sanding
dust. Keep away from heat, sparks and flame. Do not smoke. Vapors may ignite explosively. Vapors may
spread long distances. Extinguish all flames, burners, stoves, heaters and pilot lights and disconnect all electrical
motors and appliances before use and until all vapors are gone. Do not breathe vapors. Prevent build-up of
vapors by opening all windows and doors to achieve cross-ventilation. Avoid contact with eyes and skin. Close
container after use. FIRST AID: For skin contact, wash thoroughly with soap and water. If any product remains,
gently rub with petroleum jelly, vegetable or mineral/baby oil, then wash again with soap and water. Repeat as
needed. Remove contaminated clothing. For eye contact, flush immediately with plenty of water for at least 15
minutes. Get medical attention. If swallowed, get medical attention immediately. If inhalation causes physical
discomfort, remove to fresh air. If discomfort persists or any breathing difficulty occurs, get medical attention. For
emergency information, customer service, MSDS or additional safety and chronic hazard information, call
1-800-634-0015. KEEP FROM FREEZING. MDS63-1006
15885 West Sprague Rd.
Strongsville, OH 44136
www.liquidnails.com
HEAVY DUTY
CONSTRUCTION ADHESIVE
Customer Service 1-800-634-0015