SAFETY DATA SHEET Issuing Date January 5, 2015 Revision Date May 13, 2019 Revision Number 2 1.
Liquid- Plumr® Industrial Strength Clog Remover Revision Date May 13, 2019 2. HAZARDS IDENTIFICATION Classification This chemical is considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200).
Liquid- Plumr® Industrial Strength Clog Remover Revision Date May 13, 2019 Interactions with Other Chemicals Reacts with other household chemicals such as ammonia, toilet bowl cleaners, acids, and non-Liquid-Plumr® drain openers to produce hazardous gases, such as chlorine and other chlorinated compounds. 3. COMPOSITION/INFORMATION ON INGREDIENTS Chemical Name CAS-No Weight % Trade Secret Sodium hypochlorite 7681-52-9 3-7 * Sodium hydroxide 1310-73-2 1 - 2.
Liquid- Plumr® Industrial Strength Clog Remover Revision Date May 13, 2019 5. FIRE-FIGHTING MEASURES Suitable Extinguishing Media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Unsuitable Extinguishing Media CAUTION: Use of water spray when fighting fire may be inefficient. Specific Hazards Arising from the Chemical This product causes burns to eyes, skin, and mucous membranes.
Liquid- Plumr® Industrial Strength Clog Remover Revision Date May 13, 2019 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Control parameters Exposure Guidelines Chemical Name Sodium hydroxide 1310-73-2 Sodium hypochlorite 7681-52-9 ACGIH TLV OSHA PEL Ceiling: 2 mg/m3 TWA: 2 mg/m3 None None NIOSH IDLH IDLH: 10 mg/m3 Ceiling: 2 mg/m3 None ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value.
Liquid- Plumr® Industrial Strength Clog Remover Revision Date May 13, 2019 9.
Liquid- Plumr® Industrial Strength Clog Remover Revision Date May 13, 2019 11. TOXICOLOGICAL INFORMATION Information on likely routes of exposure Product Information . Inhalation Exposure to vapor or mist may irritate respiratory tract and cause coughing. Inhalation of high concentrations may cause pulmonary edema. Eye Contact Corrosive. May cause severe damage to eyes. Skin Contact May cause severe irritation to skin. Prolonged contact may cause burns to skin.
Liquid- Plumr® Industrial Strength Clog Remover Revision Date May 13, 2019 Numerical measures of toxicity - Product Information The following values are calculated based on chapter 3.1 of the GHS document ATEmix (oral) 45 g/kg ATEmix (dermal) 77 g/kg (ATE) ATEmix (inhalation-dust/mist) 33 mg/L 12. ECOLOGICAL INFORMATION Ecotoxicity Very toxic to aquatic life with long lasting effects. Persistence and Degradability No information available. Bioaccumulation No information available.
Liquid- Plumr® Industrial Strength Clog Remover Revision Date May 13, 2019 15. REGULATORY INFORMATION Chemical Inventories TSCA DSL/NDSL All components of this product are either on the TSCA 8(b) Inventory or otherwise exempt from listing. All components are on the DSL or NDSL. TSCA - United States Toxic Substances Control Act Section 8(b) Inventory DSL/NDSL - Canadian Domestic Substances List/Non-Domestic Substances List U.S.
Liquid- Plumr® Industrial Strength Clog Remover Revision Date May 13, 2019 US State Regulations California Proposition 65 This product does not contain any Proposition 65 chemicals. U.S. State Right-to-Know Regulations Chemical Name Sodium hypochlorite 7681-52-9 Sodium hydroxide 1310-73-2 New Jersey Massachusetts Pennsylvania Rhode Island X X X X X X X X Illinois International Regulations Canada WHMIS Hazard Class E - Corrosive material 16.