Operating Instructions

Sensor 01
Startup
26
Print version 03/2021, English
You will notice whether or not the magnets are holding the sensor.
6. The surface is not suitable for attachment if the magnets do not hold the sensor. Find
another surface and repeat the previous step.
CAUTION! Risk of injury from dropping sensor! Release the sensor only
slowly. This allows you to see whether or not it is slipping or moving. Hold on to the
sensor if it slips or moves. You can thus prevent minor injuries to your feet and
damage to the sensor.
The magnets of the sensor are strong and hold it in position.
7. Attach the warning and safety notices provided around the sensor.
Fig. 16: Attaching warnings (example)
8. Insert the two connecting lines into the coolant tank.
Fig. 17: Hose lines in the coolant tank
9. Check the lengths of the hose lines. The distance between the sensor and the surface of
the coolant must not be greater than 1.5 meters. Also, take a lower liquid level in the tank
into account here!