User's Manual

Data Sheet: CR Series
JukeBlox Networked Media Modules
dat_CR860_CR870_2_14_datasheet.doc CONFIDENTIAL Version 2.14 – June 10
th
2010 - Page 7 of 15
Regulatory compliance
Description Country Compliance
Electromagnetic Compatibility
(Prescan)
USA
Europe
FCC CFR47 Part15B
EN 55022
EN 55024
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Radio Regulations (CM870
only)
TBD TBD
RoHS
Uses only RoHS compliant components
Environmental Test
Withstands 4 hours at 70°C, 90% RH
ESD and Transient Test (Applies to LAN and USB external
connections only)
ESD: +/- 2kV operation, +/- 4kV no destruction (part of CE test)
Fast electrical transients: +/- 500V operation, +/- 1000V no destruction (part of CE test)
Magnetic Field Test
Passes EN55022 and EN55024 (part of CE test)
MTBF
>10000 hours
Mechanical Specifications
Passes drop test according to I.E.C. 68-2-32, height 100 cm, 1 corner, 6 faces.
Passes vibration test with sine, vertical, 60 minutes, 600 to 18000 cpm, 1G
Module Quality
Defect Rate: 7 months <0.5% failures, 14 months <1% failures
AQL CR=0, MA=0.4, MI=0.4