Datasheet

LITE-ON TECHNOLOGY CORPORATION
P r o p e r t y o f L i t e - O n O n l y
Electrical Optical Characteristics at T
A
=25
Parameter
Symbol
Color
Min.
Typ.
Max.
Unit
Test Condition
Luminous Intensity
I
V
Red Orange
Green
12.6
12.6
19
19
100
100
mcd
I
F
= 20mA
Note 1,4
Viewing Angle
2
θ
1/2
Red Orange
Green
75
75
deg
Note 2 (Fig.6)
Peak Emission Wavelength
λ
p
Red Orange
Green
630
565
nm
Measurement
@Peak (Fig.1)
Dominant Wavelength
λ
d
Red Orange
Green
615
565
625
573
632
578
nm
Note 3
Spectral Line Half-Width
Δλ
Red Orange
Green
40
30
nm
Forward Voltage
V
F
Red Orange
Green
2.0
2.1
2.6
2.6
V
I
F
= 20mA
Reverse Current
I
R
Red Orange
Green
100
μ
A
Note 5
V
R
= 5V
Note: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
(Commission International De L'Eclairage) eye-response curve.
2.
θ
1/2
is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. The dominant wavelength,
λ
d
is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
4. The Iv guarantee should be added
±
15% .
5. Reverse Voltage (V
R
) condition is applied for IR test only. The device is not designed for reverse operation.
Part No. : LTL-1BEHJ
Page : 3 of 10
BNS-OD-C131/A4