Specification

2AV 2x2 Direct/Indirect Lighting
10˚ 30˚
50˚
70˚
90˚
90˚
100
200
300
400
500
600
700
800
Coefficients of Utilization
pf 20%
pc 80% 70% 50%
pw 70%50%30% 50%30%10% 50%30%10%
70
64
58
53
48
44
41
38
35
33
31
70
61
53
47
41
37
33
30
27
25
23
70
58
49
42
36
31
28
25
22
20
18
68
60
52
46
40
36
33
29
27
25
23
68
57
48
41
36
31
28
25
22
20
18
68
55
45
38
32
27
24
21
19
17
15
65
57
50
44
39
35
31
29
26
24
22
65
55
47
40
35
30
27
24
22
20
18
65
54
44
37
31
27
24
21
19
17
15
RCR
0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone Lumens % Lamp% Fixture
0˚ - 30˚
0˚ - 40˚
0˚ - 60˚
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
666
1095
1944
2461
0
2461
15.9
26.1
46.3
58.6
0.0
58.6
27.1
44.5
79.0
100.0
0.0
100.0
Efficiency: 58.6%
CP Summary
90
15˚
25˚
35˚
45˚
55˚
65˚
75˚
85˚
90
847
847
816
752
659
536
392
241
110
26
0
847
850
826
786
714
619
502
366
183
39
0
2AV G 3 17 MDR, (3) 17W T8 lamps, 1400 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL9106
2AV G 3 17 SBL, (3) 17W T8 lamps, 1325 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL10191
10˚ 30˚
50˚
70˚
90˚
90˚
200
400
600
800
1000
Coefficients of Utilization
pf 20%
pc 80% 70% 50%
pw 70%50%30% 50%30%10% 50%30%10%
83
76
69
63
58
53
49
45
42
40
37
83
73
63
56
49
44
40
36
33
30
28
83
70
59
50
43
38
33
30
27
24
22
81
71
62
55
48
43
39
35
32
30
27
81
68
58
49
43
37
33
30
27
24
22
81
66
54
45
38
33
29
25
23
20
19
78
68
60
52
47
42
38
34
31
29
27
78
66
56
48
42
37
32
29
26
24
22
78
64
53
44
38
33
28
25
23
20
18
RCR
0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone Lumens % Lamp% Fixture
0˚ - 30˚
0˚ - 40˚
0˚ - 60˚
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
768
1253
2199
2780
0
2780
19.3
31.5
55.3
69.9
0.0
69.9
27.6
45.1
79.1
100.0
0.0
100.0
Efficiency: 69.9%
CP Summary
90
15˚
25˚
35˚
45˚
55˚
65˚
75˚
85˚
90
1001
997
941
846
720
568
404
267
143
34
0
1001
985
963
914
835
719
581
403
188
36
0
*DGA accessory available to provide ceiling trim ange and xture support for plaster or plasterboard ceiling. Recommended rough-in dimensions for DGA installation is 24-3/4" x 24-3/4" (Tolerance is +1/8", -0).
STGSTG
Lay-in trim (exposed grid tee),
air fixtures
La y-in trim (exposed grid tee Screw slot trim (screw slot tee)
)
Screw slot trim (screw slot tee),
air fixtures
2AV-2X2 T8
FLUORESCENT: One Lithonia Way, Conyers, GA 30012 Phone: 800-858-7763 Fax: 770-929-8789 www.lithonia.com © 2007-2014 Acuity Brands Lighting, Inc. All rights reserved. Rev. 08/04/14
MOUNTING DATA
Appropriate
Ceiling Type Trim Type
Exposed grid tee (1' and 9/16") G
Concealed grid tee G
Screw slot ST
Plaster or plasterboard G*