Specification Sheet
2BLT Volumetric Recessed Lighting 2'x2'
2BLT2X2
LED: One Lithonia Way Conyers, GA 30012 Phone: 800-858-7763 www.lithonia.com © 2015-2016 Acuity Brands Lighting, Inc. All rights reserved. Rev. 12/19/16
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: 2BLT2 33L ADP EZ1 LP835
2BLT2
Series Air function Lumens
2
Diffuser Voltage Driver Color temperature
2BLT2 2X2 BLT (blank) Static
A Air
supply/
return
Standard
efficiency
(>100 LPW )
20L 2000
33L 3300
40L 4000
High
efficiency
(>130 LPW )
33LHE 3300
40LHE 4000
48LHE 4800
ADP Curved, linear prisms
ADSM Curved, smooth
SDP Square, linear prisms
SDSM Square, smooth
Includes trim rings to match
sensored version
ADPT Curved, linear prisms
ADSMT Curved, smooth
SDPT Square, linear prisms
SDSMT Square, smooth
(blank) MVOLT
120 120V
277 277V
347 347V
5
EZ1 eldoLED dims to
1% (0-10 volt
dimming)
SLD Step-level
dimming
6
LE1 Lutron Ecosystem
driver dims to
1%
6,7
LP830 82CRI, 3000 K
LP835 82CRI, 3500 K
LP840 82CRI, 4000 K
LP850 82CRI, 5000 K
LP930 90CRI, 3000K
LP935 90CRI, 3500K
LP940 90CRI, 4000K
LP950 90CRI, 5000K
Controls Occupancy control
10
Options
(blank) No nLight
®
N80 nLight
® with 80%
lumen management
N80EMG nLight
®
with
80% lumen
management For
use with generator
supply EM power
8
N100 nLight
®
without lumen
management
N100EMG nLight
®
without lumen
management For
use with generator
supply EM power
8
NLTAIR nLight AIR enabled
9
(blank) No sensor control
nLight Wired Networking
NES7 nLight™
nES 7 PIR integral
occupancy sensor
11
NESPDT7 nLight™ nES PDT 7 dual
technology integral
occupancy control
11
NES7ADCX nLight™ nES 7 ADCX PIR
integral occupancy sensor
with automatic dimming
photocell
11
NESPDT7ADCX nLight™ nES PDT 7 dual
technology integral
occupancy sensor with
automatic dimming
photocell
11
nLight Wireless Networking
RES7N
nLight AIR PIR integral
occupancy sensor with
automatic dimming photocell
for Networking Capabilities
Individual Control
MSD7ADCX PIR integral
occupancy sensor
with automatic
dimming control
photocell
6,12
MSDPDT7ADCX PDT integral
occupancy sensor
with automatic
dimming control
photocell
6,12
nLight Wireless Zone
RES7Z nLight AIR
PIR integral
occupancy sensor
with automatic
dimming
photocell for
zone control
EL7L 700 lumen battery pack
13
EL14L 1400 lumen battery pack
13
EL14LSD 1400 lumen battery pack with self-diagnostic testing
feature
13,14
CP Chicago plenum
15
BGTD Bodine Generator Transfer Device
16
PWS1836 6’ pre-wire, 3/8” diameter, 18 gauge, 1 circuit
PWS1846 6’ pre-wire, 3/8” diameter, 18 gauge, 2 circuit
PWS1846 PWSLV Two cables: one 6' pre-wire, 3/8” diameter, 18 gauge, 2
circuits; one 6' pre-wire, 3/8” diameter, 18 gauge, purple
and gray
17
PWS1856LV 6’ pre-wire, 3/8” diameter, 18 gauge, 1 circuit w/low voltage
purple and grey wires
17
GLR Fast-blowing fuse
18
GMF Slow-blowing fuse
18
NPLT Narrow pallet
RRL_ RELOC®-ready luminaire
19
LATC Earthquake clip
DWAM Anti-Microbial paint
JP32 Job packaging
IP5X Gasketed diffuser compartment to meet IP5X rating
20
Notes
1 Air supply/return option only available with ADPT, ADSMT, SDPT, and
SDSMT diffuser options.
2 Approximate lumen output.
3 All versions may not achieve 130+ LPW. Refer to photometry on www.
acuitybrands.com.
4 Air supply/return option, 90 CRI, and versions with integral sensor trim
rings may not achieve 130 LPW.
5 Not available with SLD EL7L, or EL14L options.
6 Not available with N80, N80EMG, N100, N100EMG, NLTAIR, or occupancy
control.
7 Not available with controls, occupancy controls, or PWS options. Consult
factory for Hi-Lume dimming.
8 nLight EMG option requires a connection to existing nLight network.
Power is provided from a separate N80 or N100 enabled fixture.
9 Must order with RES7N or RES7Z sensor. Only available with EZ1 driver.
10 Must specify diffuser with trim rings. See sensor options on page 4.
11 Requires N80, N80EMG, N100, or N100EMG.
12 Only available with EZ1 driver option. 0-10v dimming wires not
accessible via access plate.
13 When using pre-wire option, use PWS1846 or PWS1846 PWSLV.
14 For more information, please see the PSSD2 specification sheet.
15 Not available with N80, N80EMG, N100, or N100EMG.
16 Must specify voltage. Requires BSE labeling, voltage specific. Consult
factory for options.
17 Not available with nLight wired/wireless network or individual controls.
18 Must specify voltage, 120 or 277, with GLR and GFM fusing.
19 For ordering logic consult RRL_2013.
20 Not available with air supply/return or Wired Networking (NES_) and
Individual Control (MSD_) sensors.
Non-Configurable BLT
Stock/MTO Catalog Description * UPC Lumens Wattage LPW Color Temperature Voltage Pallet Qty
Stock 2BLT2 33L ADP LP835 00190887529708 3241 30 108 3500K/82 CRI 120-277 52
2BLT2 33L ADP LP840 00190887529739 3313 30 111 4000K/82CRI 120-277 52
2BLT2 33L ADP EL14L LP835 00190887529890 3241 30 108 3500K/82CRI 120-277 52
2BLT2 33L ADP EL14L LP840 00190887529937 3313 30 111 4000K/82CRI 120-277 52
MTO 2BLT2 33L ADP 347 LP835 3241 30 108 3500K/82 CRI 347 52
2BLT2 33L ADP 347 LP840 3313 30 111 4000K/82CRI 347 52
*Generic 0-10V Dimming to 10%.
Accessories next page
A+ Capable options indicated
by this color background.