ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: 2BLT2 33L ADP EZ1 LP835
2BLT2
Series Air function Lumens
2
Diffuser Voltage Driver Color temperature
2BLT2 2X2 BLT (blank) Static
A Air
supply/
return
Standard
efficiency
(>125 LPW)
20L 2000
33L 3300
40L 4000
48L 4800
High
efficiency
(>130 LPW )
20LHE 2000
33LHE 3300
40LHE 4000
48LHE 4800
ADP Curved, ribbed
ADSM Curved, smooth
SDP Square, ribbed
SDSM Square, smooth
Includes trim rings to match
sensored version
ADPT Curved, ribbed
ADSMT Curved, smooth
SDPT Square, ribbed
SDSMT Square, smooth
(blank) MVOLT
120 120V
277 277V
347 347V
7
EZ1 eldoLED dims to
1% (0-10 volt
dimming)
GZ1 Dims to 1% (0-
10V dimming)
8
GZ10 Dims to 10% (0-
10V dimming)
8
SLD Step-level
dimming
9
LP830 82CRI, 3000 K
LP835 82CRI, 3500 K
LP840 82CRI, 4000 K
LP850 82CRI, 5000 K
LP930 90CRI, 3000K
LP935 90CRI, 3500K
LP940 90CRI, 4000K
LP950 90CRI, 5000K
A+ Capable options indicated
by this color background.
Notes
1 Consult factory for airflow data.
2 Approximate lumen output.
3 All versions may not achieve 125+ LPW. Refer to photometry on
www.acuitybrands.com.
4 Air supply/return option, 90 CRI, and versions with integral sensor trim
rings may not achieve 125 LPW.
5 All versions may not achieve 130+ LPW. Refer to photometry on
www.acuitybrands.com.
6 Air supply/return option, 90 CRI, and versions with integral sensor trim
rings may not achieve 130 LPW.
7 Not available with SLD, EL7L, EL14L or E10WLCP options.
8 GZ1 and GZ10 not available with any Control or Sensor options
9 Not available with N80, N80EMG, N100, N100EMG, NLTAIR2, or
occupancy control.
10 nLight EMG option requires a connection to existing nLight network.
Power is provided from a separate N80 or N100 enabled fixture.
11 Must order with RES7, RES7PDT or RIO module. Must order with EZ1
driver.
12 Must specify diffuser with trim rings. See sensor options on page 4.
13 Requires N80, N80EMG, N100, or N100EMG. Must order with EZ1 driver.
14 Only available with EZ1 driver option. 0-10v dimming wires not
accessible via access plate.
15 Can only be ordered in conjunction with EZ1, NLTAIR2, RES7/RES7PDT.
Occupancy sensor disabled at factory but can be re-enabled upon
commissioning.
16 When using pre-wire option, use PWS1846 or PWS1846 PWSLV.
17 For more information, please see the PSSD2 specification sheet.
18 Not available with N80, N80EMG, N100, or N100EMG.
19 Must specify voltage. Requires BSE labeling, voltage specific. Consult
factory for options.
20 Not available with nLight wired/wireless network or individual controls.
21 Must specify voltage, 120 or 277, with GLR and GFM fusing.
22 For ordering logic consult RRL_2013.
23 Only available with options: NES7, NESPDT7, NES7ADCX, NESPDT7ADCX,
MSD7ADCX, MSDPDT7ADCX, RES7, RES7PDT, RIO.
24 Not available with air supply/return or Wired Networking (NES_) and
Individual Control (MSD_) sensors.
25 See UL924 Sequence of Operation chart on page 3.
nLight Interface Control
12
nLight Wired
(blank) no nLight ® interface
N80
nLight with 80% lumen management
N80EMG nLight with 80% lumen management
For use with generator supply EM power
10
N100 nLight without lumen management
N100EMG nLight without lumen management
For use with generator supply EM power
10
nLight Wireless
(blank) no nLight ® interface
NLTAIR2
nLight AIR Generation 2 enabled
11
nLight Wired
(blank) No sensor control
NES7
nLight™ nES 7 PIR integral occupancy sensor
13
NESPDT7
nLight™ nES PDT 7 dual technology integral occupancy control
13
NES7ADCX
nLight™ nES 7 ADCX PIR integral occupancy sensor with
automatic dimming photocell
13
NESPDT7ADCX
nLight™ nES PDT 7 dual technology integral occupancy sensor
with automatic dimming photocell
13
nLight Wireless
RES7 nLight AIR PIR integral occupancy sensor with automatic
dimming photocell for Networking Capabilities
RES7PDT nLight AIR microphonics dual technology occupancy sensor
with automatic dimming photocell
RIO nLight AIR radio module without sensor
RES7EM nLight AIR PIR integral occupancy sensor with automatic
dimming photocell and UL924 Emergency Operation, via
power interrupt detection
25
RES7PDTEM nLight AIR microphonics dual technology occupancy sensor
with automatic dimming photocell and UL924 Emergency
Operation, via power interrupt detection
25
RIOEM nLight AIR radio module less sensor, with UL924 Emergency
Operation, via power interrupt detection
25
Individual Control
MSD7ADCX PIR integral occupancy sensor with
automatic dimming control photocell
14
MSDPDT7ADCX PDT integral occupancy sensor with
automatic dimming control photocell
14
Standy Mode Options
NOC NOC Occupancy
sensor disabled
15
RIB Ribbed reflector
EL7L 700 lumen battery pack
(Noncompliant with CA T20)
16
EL14L 1400 lumen battery pack
(Noncompliant with CA T20)
16
EL14LSD 1400 lumen battery pack with
self-diagnostic testing feature
(Noncompliant with CA T20)
16,17
E10WLCP EM Self-Diagnostic battery pack,
10W Constant Power, Certified in
CA Title 20 MAEDBS
16
CP Chicago plenum
18
BGTD Bodine Generator Transfer Device
19
PWS1836 6’ pre-wire, 3/8” diameter, 18 gauge, 1 circuit
PWS1846 6’ pre-wire, 3/8” diameter, 18 gauge, 2 circuit
PWS1846 PWSLV Two cables: one 6' pre-wire, 3/8” diameter,
18 gauge, 2 circuits; one 6' pre-wire, 3/8”
diameter, 18 gauge, purple and gray
20
PWS1856LV 6’ pre-wire, 3/8” diameter, 18 gauge, 1 circuit
w/low voltage purple and grey wires
20
GLR Fast-blowing fuse
21
GMF Slow-blowing fuse
21
NPLT Narrow pallet
RRL_ RELOC®-ready luminaire
22
LATC Earthquake clip
DWAM Anti-Microbial paint
JP28 Job packaging
23
JP36 Job packaging
IP5X
Gasketed diffuser compartment
to meet IP5X rating