Specification

FEATURES & SPECIFICATIONS
INTENDED USE Low-prole static luminaire provides general illumination for recessed applications;
Ideal for restricted plenum spaces.
Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental
Compatibility table for suitable uses.
ATTRIBUTES
Designed exclusively for use with T8 lamps, electronic ballasts and sockets.
CONSTRUCTION
Smooth hemmed sides and smooth, inward formed end anges for safe handling.
Lighter weight xture allows for safe, easy installation.
Standard steel door frame has superior structural integrity with premium extruded appearance and precision
ush mitered corners. Steel door allows easy lens replacement without frame disassembly (for lenses up to
.156" thick). Powder painted, steel latches provide easy, secure door closure.
Superior mechanical light seal requires no foam gasketing. Integral T-bar clips secure xture to T-bar
system. Housing formed from cold-rolled steel. Acrylic shielding material 100% UV stabilized. No asbestos
is used in this product.
FINISH
Five-stage iron-phosphate pretreatment ensures superior paint adhesion and rust resistance.
Painted parts nished with high-gloss, baked white enamel.
ELECTRICAL
Standard ballast is electronic, thermally protected, resetting, Class P, HPF, non-PCB, UL Listed,
CSA certied ballast, universal voltage and sound rated A.
Luminaire is suitable for damp locations. AWM, TFN or THHN wire used throughout, rated for required
temperatures.
LISTING
Standard: UL. Optional: Canada — CSA or cUL.
WARRANTY — 1-year limited warranty. Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
US patents: 6,210,025; 6,231,213; 2,288,471.
Note: Actual performance may dier as a result of end-user environment and application.
Specications subject to change without notice.
General Purpose T8 Troer
GT8 2'x4'
2, 3 or 4 Lamps
Specications
Length: 48 (121.8)
Width: 24 (60.9)
Depth: 3-3/16 (8.1)
Weight: 22 lbs (9.9 kg)
All dimensions are inches (centimeters).
24
(60.9)
3-3/16
(8.1)
48
(121.8)
NOTES:
1 MVOLT standard for 120-277V applications, 50-60 hz
operation.
2GT8
Series Trim type
Number of
lamps Lamp type Door frame Diuser type Voltage Options
2GT8 2' wide (blank) Grid 2
3
4
Not
included
32 32W T8 (48") (blank) Flush steel,
white
A12 #12 pattern
acrylic
MVOLT
1
1/4 One 4-lamp ballast
1/3 One 3-lamp ballast
MVIS Electronic ballast, instant start
PWS1836 6' prewire, 3/8" dia., 18-gauge,
1 circuit
LP_ Lamped, specify lamp type
and color
CSA CSA Certied
ORDERING INFORMATION
For shortest lead times, congure products using bolded options.
Example:
2GT8 2 32 A12 MVOLT MVIS
Catalog
Number
Notes
Type
FLUORESCENT: GT8-2X4-MVIS

Summary of content (2 pages)