Specification
MOUNTING DATA
Continuous row mounting of anged units requires CRE and CRM trim options
(see Options).
GT8 2'x4' Static T8 Troer
DIMENSIONS
PHOTOMETRICS
Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reectances are 20%.
Lamp congurations shown are typical. Full photometric data on these and other congurations available upon request.
2GT8 4 32 A12 1/4
Report LTL 7425
Lumens per lamp - 2850 – Lum. e. - 78.6%
S/MH (along) 1.2 (across) 1.4
Coecient of Utilization
Ceiling 80% 70% 50%
Wall 70% 50% 30% 70% 50% 30% 50% 30% 10%
0 94 94 94 91 91 91 87 87 87
1 86 82 79 84 81 78 77 75 73
2 79 73 68 77 71 67 68 64 61
3 72 64 58 70 63 57 61 56 52
4 66 57 51 65 56 50 54 49 45
5 61 51 45 60 51 44 49 43 39
6 57 47 40 55 46 39 44 39 34
7 53 42 36 51 42 35 40 35 31
8 49 39 32 48 38 32 37 31 27
9 46 35 29 45 35 29 34 29 25
10 43 33 27 42 32 27 32 26 22
Zonal Lumens Summary
Zone Lumens %Lamp %Fixture
0-30 2718 23.8 30.3
0-40 4481 39.3 50.0
0-60 7553 66.3 84.2
0-90 8965 78.6 100.0
90-180 0 0 0
0-180 8965 78.6 100.0
2GT8 2 32 A12
Report LTL 7424
Lumens per lamp - 2850 – Lum. e. - 81.7%
S/MH (along) 1.2 (across) 1.4
Coecient of Utilization
Ceiling 80% 70% 50%
Wall 70% 50% 30% 70% 50% 30% 50% 30% 10%
0 97 97 97 95 95 95 91 91 91
1 89 86 82 87 84 81 80 78 76
2 82 75 70 80 74 69 71 67 63
3 75 67 60 73 65 59 63 58 54
4 69 59 52 67 58 52 56 51 46
5 63 53 46 62 52 46 51 45 40
6 59 48 41 47 47 40 46 40 35
7 54 44 37 53 43 36 42 36 31
8 51 40 33 49 39 33 38 32 28
9 47 37 30 46 36 30 35 29 25
10 44 34 27 43 33 27 32 27 23
Zonal Lumens Summary
Zone Lumens %Lamp %Fixture
0-30 1372 24.1 29.4
0-40 2277 39.9 48.9
0-60 3907 68.5 83.9
0-90 4658 81.7 100.0
90-180 0 0 0
0-180 4658 81.7 100.0
2GT8 3 32 A12 1/3
Report LTL 7421
Lumens per lamp - 2850 – Lum. e. - 80.1%
S/MH (along) 1.2 (across) 1.4
Coecient of Utilization
Ceiling 80% 70% 50%
Wall 70% 50% 30% 70% 50% 30% 50% 30% 10%
0 95 95 95 93 93 93 89 89 89
1 88 84 81 85 82 79 79 76 74
2 80 74 69 78 72 68 70 66 62
3 74 66 59 72 64 58 62 57 53
4 68 58 52 66 57 51 55 50 46
5 62 52 45 61 52 45 50 44 40
6 58 47 40 56 47 40 45 39 35
7 54 43 36 52 42 36 41 35 31
8 50 39 33 49 39 32 38 32 28
9 47 36 30 45 36 29 35 29 25
10 44 33 27 43 33 27 32 27 23
Zonal Lumens Summary
Zone Lumens %Lamp %Fixture
0-30 2066 24.2 30.2
0-40 3412 39.9 49.8
0-60 5768 67.5 84.2
0-90 6851 80.1 100.0
90-180 0 0 0
0-180 6851 80.1 100.0
4-7/8
(12.4)
6-15/16
(17.8)
6-15/16
(17.8)
6-15/16
(17.8)
24
(60.9)
24
(60.9)
2-9/16
(6.5)
3-3/16
(8.1)
3-3/16
(8.1)
24
(60.9)
3-3/16
(8.1)
GT8-2X4-MVIS
FLUORESCENT: One Lithonia Way Conyers, GA 30012 Phone: 800-858-7763 www.lithonia.com ©1999-2016 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/08/16