Specification

PHOTOMETRICS
Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reectances are 20%. Lamp congurations shown are typical. All data based on 25°C.
Full photometric data on these and other congurations available upon request.
AF
DIMENSIONS
A = 1/4 x 1/2 (64 x 13) Oval Hole
C = 7/8 (22) Dia.K.O.
D = 11/16 (17) Dia. K.O.
E = 2 (51) Dia. K.O.
F = 7/16 (111) Dia. K.O.
All dimensions are inches (millimeters).
Specications subject to change without notice.
MOUNTING DATA
For unit or row installation. Surface or stem mounting.
1
UNIT INSTALLATION — Minimum of two hangers required.
ROW INSTALLATION — One hanger per xture plus one per row required.
2
(5.1)
6-5/8
(16.8)
6-5/8
(16.8)
13-3/8
(34.0)
13-3/8
(34.0)
AF 2 32
Report ITL 5711
S/MH 1.4
Coecient of Utilization
Ceiling 80% 70% 50%
Wall 70% 50% 30% 70% 50% 30% 50% 30% 10%
1 94 90 86 90 86 83 79 76 74
2 86 79 73 82 75 70 69 65 61
3 78 69 62 74 66 60 61 56 52
4 72 61 54 68 59 52 54 48 44
5 65 54 46 62 52 44 48 41 37
10 43 31 24 41 30 23 28 22 18
Zonal Lumens Summary
Zone Lumens %Lamp %Fixture
0-30 998 17.2 19.0
0-40 1677 28.9 31.9
0-60 3126 53.9 59.6
0-90 4074 70.2 77.6
90-180 1175 20.3 22.4
0-180 5249 90.5 100.0
AF
INDUSTRIAL: One Lithonia Way Conyers, GA 30012 Phone: 800-315-4963 Fax: 770-981-8191 www.lithonia.com ©1996-2014 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/31/14
1B
HRUN
SQ
HC36
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Energy (Calculated in accordance with NEMA standard LE-5)
LER.FW
ANNUAL
ENERGY COST*
LAMP
DESCRIPTION
LAMP
LUMENS
BALLST
FACTOR
WATTS
74 $3.24 (2) F32T8 2800 .88 60
*Calculated in accordance with NEMA Standards LE-5.