Specification

FEATURES & SPECIFICATIONS
INTENDED USE Ideal where high brightness and good illumination levels are required such as retail,
light industrial and warehouses.
Attributes: Available in one lamp or two lamp conguration.
CONSTRUCTION
Heavy-duty channel, die-formed from code-gauge steel.
Sturdy channel cover secured by captive quarter-turn latch for easy access to wireway.
Combination endplate/channel connector furnished with each xture.
Finish: Five-stage iron phosphate pretreatment ensures superior paint adhesion and rust resistance. Painted
parts nished with high-gloss, baked white enamel.
ELECTRICAL
Thermally protected, resetting, Class P, UL Listed and CSA Certied ballast is standard.
Sound rating depends on lamp/ballast combination.
AWM, TFN, THHN wire throughout, rated for required temperatures.
INSTALLATION
For unit or row installations, surface or suspended mounting.
LISTINGS
UL listed to US and Canadian safety standards. Optional: Mexico NOM.
Damp location listed.
Listed for 25 degree C ambient temperature.
WARRANTY
1-year limited warranty. Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx .
Note: Specications subject to change without notice.
Actual performance may dier as a result of end-user environment and application.
C
Series Number of lamps Lamp type Voltage
C General-purpose strip
For tandem double length unit,
add prex T. Example: TC
1
2
lamp not included
T8
17 17W T8 (24”)
25 25W T8 (36”)
32 32W T8 (48”)
48T8 38W T8 (48”)
96T8 59W T8 slimline (96”)
T12 Slimline
36 30W slimline (36”)
48 38W slimline (48”)
72 55W slimline (72”)
96 75W slimline (96”)
HO
24HO 35W T12 800mA (24”)
1
36HO 45W T12 800mA (36”)
1
48HO 60W 800mA (48”)
48T8HO 44W T8 (48”)
72HO 85W 800mA (72”)
72T8HO 65W T8 (72”)
96HO 110W 800mA (96”)
96T8HO 86W 380mA (96”)
MVOLT
2
120
277
347
Others available
Options
GEB
Electronic ballasts, <20%THD
4
GEB10IS
Electronic ballasts, <10%THD, instant start
2
GEB10RS
Electronic ballast, <10%THD, rapid start
3
GEB10PS
Electronic ballast, <10%THD, programmed start
BILP
High-eciency ballast, .78bf (low), instant start
BINP
T8 high-performance ballast, .88bf (normal), instant start
BIHP
T8 high-performance ballast, 1.20bf (high), instant start
1/4
One four-lamp ballast
5
EL
Emergency battery pack (nominal 300 lumens)
6
GLR
Internal fast-blow fuse (add X for external)
6
GMF
Internal slow-blow fuse (add X for external)
6
PLR_
Plug-in wiring; specify 1, 2, or 3 branch circuits and hot wires (A = Black, B = Red, C = Blue, AB or AC)
6
TILW
Tandem in-line wiring
CSA
CSA Certied (only required for 347V)
NOM
NOM Certied
AL
Aluminum housing; white enamal nish
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: C 2 32 MVOLT GEB10IS
INDUSTRIAL C
Catalog
Number
Notes
Type
General-Purpose Strip
C
2’, 3’, 4', 6’ and 8' length
1 or 2 lamps
Notes
1 Only avaialble with AL option.
2 MVOLT standard for 120-277V applications, 50-60 mhz operation.
Some options require voltage specied.
3 347V, simline lamps only.
4 Slimline and HO lamps only.
5 Not available in slimline.
6 Specify voltage.
7 Order two for 8’ xtures.
Accessories: Order as separate catalog number.
SQ_ Swivel stem hanger (specify length in 2” increments) HRC1® Hooker T-bar hanger (1-1/2” from ceiling)
1B Ceiling spacer (adjusts from 1-1/2” to 2-1/2” from ceiling) WGCSMR48 Wireguard, 4’ white for symmetric reector
7
CONLGC 12” screw-on channel connector WGCASR48 Wireguard, 4’ white for asymmetric reector
7
WGCUN NST Wireguard, 4’ white
7
CSMR 48 Symmetric reector, 4’ white, 7” aperture
7
HC36 Chain hangers (1 pair, 36” long) CASR 48 Asymmetric reector, 4’ white, 5-3/4” wide
7
HRC® Hooker T-bar hanger (ush to ceiling)
All dimensions are inches (centimeters)
unless otherwise specied.
Specications
Length: 24” (61.0)
36” (91.4)
48” (121.9)
72” (182.9)
96” (243.8)
Width: 4-3/8” (11.1)
Fixture Depth: 2-1/16” (5.2)

Summary of content (2 pages)