Specification Sheet

LOW_PROFILE_STRIPS
CONTRACTOR SELECT / FLUORESCENT: One Lithonia Way Conyers, GA 30012 Phone: 800.315.4963 Fax: 770-981-8191 www.lithonia.com ©2009-2010 Acuity Brands Lighting, Inc. All rights reserved. Rev. 08/09/10
Strip Lights
PHOTOMETRICS
Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reectances are 20%. Lamp congurations shown are typical. All data based on 25°C. Full photometric data on these and other congurations available upon request.
DIMENSIONS
Inches (millimeters). Subject to change without notice.
48", 72" and 96" have only two 7/8" K.O.'s 6" from each end
24" and 36" have only two 7/8" K.O.'s 3-1/4" from each end
Coefficients of Utilization
%02fp
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
RCR
0
1
2
3
4
5
6
7
8
9
10
103
86
74
64
56
49
44
40
36
33
30
103
82
67
56
47
41
36
32
28
25
23
103
78
61
49
41
35
30
26
23
20
18
98
82
70
61
53
47
42
38
35
32
29
98
78
64
54
46
39
34
30
27
25
22
98
74
59
48
40
34
29
25
22
20
18
90
75
64
56
49
43
39
35
32
29
27
90
72
59
49
42
37
32
28
25
23
21
90
69
55
44
37
31
27
24
21
19
17
Zonal Lumen Summary
Zone Lumens % Lamp% Fixture
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
1785.8
3042.4
5944.0
9027.5
2341.8
11369.4
14.2
24.1
47.2
71.6
18.6
90.2
15.7
26.8
52.3
79.4
20.6
100.0
TEST NO: LTL 18310
C296
LUMENS PER LAMP: 6300
Coefficients of Utilization
%02fp
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
RCR
0
1
2
3
4
5
6
7
8
9
10
106
89
76
65
57
51
45
41
37
34
31
106
84
68
57
48
42
36
32
29
26
23
106
79
62
50
42
35
30
26
23
20
18
102
85
72
62
55
48
43
39
35
32
30
102
80
66
55
47
40
35
31
28
25
23
102
76
60
49
40
34
29
25
22
20
18
93
78
66
57
50
44
40
36
33
30
28
93
74
61
51
43
37
33
29
26
23
21
93
71
56
45
38
32
28
24
21
19
17
Zonal Lumen Summary
Zone Lumens % Lamp% Fixture
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
842.1
1435.8
2810.1
4362.5
1021.0
5383.6
14.5
24.8
48.4
75.2
17.6
92.8
15.6
26.7
52.2
81.0
19.0
100.0
TEST NO: LTL 5181
C232 MV
LUMENS PER LAMP: 2900
C STRIPS
S STRIPS
Coefficients of Utilization
%02fp
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
RCR
0
1
2
3
4
5
6
7
8
9
10
107
87
74
64
56
49
44
40
36
33
30
107
82
66
55
47
40
35
31
28
25
22
107
77
60
48
40
33
29
25
22
19
17
102
83
70
61
53
47
42
38
34
31
29
102
78
63
53
45
39
34
30
27
24
22
102
74
57
46
38
32
28
24
21
19
17
92
75
63
55
48
42
38
34
31
29
26
92
71
58
48
41
35
31
27
25
22
20
92
68
53
43
35
30
26
22
20
18
16
Zonal Lumen Summary
Zone Lumens % Lamp% Fixture
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
356.4
603.9
1198.3
2029.3
602.8
2632.0
12.7
21.6
42.8
72.5
21.5
94.0
13.5
22.9
45.5
77.1
22.9
100.0
TEST NO: LTL17128
LUMINAIRE CATALOG NO.: Z132 MV
LUMENS PER LAMP: 2800
D = 11/16 (17) Dia.K.O.
E = 7/8 (22) Dia.K.O.
F = 1-1/4 (32) Dia.K.O.
H = 2 (51) Dia.K.O.