Technical Specifications
®
SPECIFICATIONS
ORDERING INFO
OPTIONS
LOW VOLTAGE RELAY (R)
• Enables sensors to interface with
other systems (e.g., BMS, lighting
panels)
• Provides dry contact closure via a
SPDT, 1 Amp, 40 Volt relay
• Only one relay needed per zone
• Changes state when all connected
sensors register unoccupied
• Relay requires sensor power to
function
OCCUPANCY CONTROLLED
DIMMING (D)
• Provides dimming output to control
0-10 VDC dimmable ballasts
• Provides a second occupancy time-
out period that enables the lights to go
to a dim setting before turning off
• Adjustable max/min dim setting
• Only one sensor per zone needs to
have dimming output
PHOTOCELL (P)
• Auto set-point calibration
• Two selectable modes of operation
• On/Off mode: Photocell has full control
during periods of occupancy
• Inhibit mode: Photocell can prevent
lights from turning on if adequate
daylight is available, but cannot turn
lights off
PHOTOCELL W/ DIMMING (ADC)
• Photocell within sensor maintains total
room light level by controlling levels of
0-10 VDC dimmable ballasts
• Photocell also has full on/off control
during periods of occupancy
• Provides a second occupancy time-
out period that enables the lights to go
to a dim setting before turning off
Note: LampMaximizer+ features not
available with ADC option
LOW TEMP/HIGH HUMIDITY (LT)
• Sensor electronics are coated for
corrosion resistance
• Operates down to -4º F (-20º C)
• Required for bathroom & cooler/
freezer applications
OVERVIEW
Open area ofce lighting control is made cost-
effective with the use of the CM PDT 9 Series
Standard Range 360° occupancy sensor. This
sensor provides line-of-sight PIR detection of
small motion in a circular pattern, and combines
overlapping Microphonics™ coverage for
detection of occupants working in their cubical
space. By installing multiple CM PDT 9s on
30 ft (9.14 m) centers, large control zones are
created (typically one per circuit of lighting). The
lighting is then controlled in blocks similar to
manual switching. Restrooms with stalls, large
storage areas with shelving, and libraries with
study carrels are also easily and cost-effectively
controlled by the CM PDT 9.
SENSOR OPERATION
Sensors with Passive Dual Technology
(PDT) rst see motion using 100% digital
Passive Infrared (PIR) detection and then
engage Microphonics™ to hear sounds that
indicate continued occupancy. This patented
technology uses Automatic Gain Control
(AGC) to dynamically self adapt a sensor
to its environment by ltering out constant
background noise and registering only noises
typical of human activity. When occupancy is
detected, a DC output goes high and can drive
up to 200 mA of connected load. If needed, a 10
second grace period also allows the lights to be
voice reactivated after shutting off. The sensor
is powered with 12-24 VAC/VDC and typically
operates with a PP20 or MP20 power pack,
enabling 20 Amp circuits to be controlled.
LAMPMAXIMIZER
®
This sensor also contains patented
LampMaximizer technology that allows users
to aggressively target energy savings while
still protecting lamp life. A minimum on timer,
factory set at 15 minutes, helps preserve lamp
life by eliminating all lamp cycles shorter than
lamp manufacturers’ recommendations. A
standard occupancy time delay is also present
that ensures lights turn off (assuming minimum
on timer has elapsed) if no occupancy is
detected. This timer is factory set at 10 minutes
to promote energy savings, but is adjustable
between 30 seconds and 20 minutes. These
adjustments can be done manually, through
the unit’s push-button, or automatically every
two weeks through an advanced mode, called
LampMaximizer+, that determines the optimum
time delay in order to maximize both lamp life
and energy savings. Additionally, this sensor
maintains statistics on total lamp on time and
number of cycles.
STANDARD RANGE 360º SENSOR
CEILING MOUNT • LOW VOLTAGE • DUAL TECHNOLOGY (PDT)
CM PDT 9
FEATURES
100% Digital PIR Detection,
Excellent RF Immunity
360º Coverage Pattern
Patented Dual Technology with
PIR / Microphonics Detection
Push-Button Programmable
Adjustable Time Delays
Convenient Test Mode
No Field Calibration or Sensitivity
Adjustments Required
100 hr Lamp Burn-in Timer
Green LED Indicator
Non-Volatile Memory
LAMPMAXIMIZER
®
TECHNOLOGY
• Protects Lamp Life while
Maximizing Energy Savings
• Minimum On Timer (15 min default)
• Occ. Time Delay (10 min default)
• LampMaximizer+ Mode -
Optimizes Lamp Life & Energy
Savings (disabled by default)
• Switch Counter (in 1000’s)
• Total Lamp On Time (in khrs)
PHYSICAL SPECS
SIZE: 4.55” Dia. (11.56 cm)
1.55” Deep (3.94 cm)
WEIGHT: 6 oz
MOUNTING:
Ceiling Tile Surface
3.5” Octagon Box
Single Gang Handy Box
COLOR: White
ELECTRICAL SPECS
OPERATING VOLTAGE:
12-24 VAC/VDC
CURRENT DRAW:
Standard, 4 mA
w/ R option, 16 mA
DIMMING LOAD: Sinks < 20mA;
~40 Ballasts @ .5mA each
RECOMMENDED POWER PACK:
PP20
ENVIRONMENTAL SPECS
OPERATING TEMP:
14º to 160º F (-10º to 71º C)
RELATIVE HUMIDITY:
20 to 90% non-condensing
SILICONE FREE
ROHS COMPLIANT
RELAY
TEMP/HUMIDITY
Blank = None Blank = None Blank = Standard
R = Low Voltage Relay D = Occupancy Controlled Dimming LT = Low Temp
P = Photocell
ADC = Photocell w/ Dimming
CM PDT 9 [RELAY] [DIMMING/PHOTOCELL] [TEMP/HUMIDITY]
DIMMING / PHOTOCELL CHOOSE ONE ONLY
C US LISTED
TITLE 24
ASSEMBLED in U.S.A.
5 YEAR WARRANTY