Specification

Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown,
within the tolerances allowed by Lighting Facts. Actual performance may differ as a result of
end-user environment and application. Actual wattage may differ by +/- 8% when operating between 120-480V +/- 10%. Contact factory for performance data
on any configurations not shown here.
To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s D-Series Flood Size 1 homepage.
Light
Engines
Drive
Current
(mA)
Performance
Package
System
Watts
Dist.
Type
Field
Angle
Beam
Angle
30K
(3000K, 70 CRI)
40K
(4000K, 70 CRI)
50K
(5000K, 70 CRI)
°H °V °H °V Max Cd Lumens LPW Max Cd Lumens LPW Max Cd Lumens LPW
1 530 A530/--K 19W
NSP
48 49 19 19 7062 1408 74 7300 1692 89 7277 1700 89
MSP
50 48 24 23 6782 1541 81 6740 1923 101 6719 1916 101
MFL
60 60 47 46 2249 1316 69 2806 1581 83 2797 1588 84
FL
85 84 63 62 1845 1752 92 1855 2105 111 1849 2115 111
WFL
106 106 71 72 1301 1739 92 1391 1995 105 1387 2099 110
WFR
107 88 85 64 1279 1764 93 1386 2119 112 1381 2129 112
HMF
100 62 80 13 1445 771 41 1259 927 49 1255 931 49
2 530 A530/--K 37W
NSP
48 49 19 19 13,379 2668 72 13,803 3206 87 13,760 3221 87
MSP
50 48 24 23 12,850 2920 79 12,744 3643 98 12,704 3631 98
MFL
60 60 47 46 4260 2493 67 5305 2995 81 5288 3009 81
FL
85 84 63 62 3496 3320 90 3507 3989 108 3496 4008 108
WFL
106 106 71 72 2465 3294 89 2630 3958 107 2622 3977 107
WFR
107 88 85 64 2422 3342 90 2620 4015 109 2612 4034 109
HMF
100 62 80 13 2738 1462 40 2381 1756 47 2374 1764 48
Performance Data
Photometric Diagrams
One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • Fax: 770.918.1209 • www.lithonia.com
© 2012-2014 Acuity Brands Lighting, Inc. All rights reserved.
Lumen Output
Current (A)
Light
Engines
Drive
Current (mA)
System
Watts
120 208 240 277 347 480
1 530 19W 0.16 0.1 0.09 0.08 -
-
2 530 37W 0.32 0.19 0.17 0.15 -
-
Electrical Load
Isocandela plots for the DSXF1 LED 2 A530/40K.
Use these factors to determine relative lumen output for
average ambient temperatures from 0-40°C (32-104°F).
Lumen Ambient Temperature
(LAT) Multipliers
Ambient Lumen Multiplier
0°C 32°F 1.07
10°C 50°F 1.04
20°C 68°F 1.02
25°C 77°F 1.00
30°C 86°F 0.98
40°C 104°F 0.95
Projected LED Lumen Maintenance
Data references the extrapolated performance projections for
the DSXF1 LED 2 A530 platform based on 8400 hours of LED
testing (tested per IESNA LM-80-08 and projected per IESNA
TM-21-11).
To calculate LLF, use the lumen maintenance factor that
corresponds to the desired number of operating hours below.
For other lumen maintenance values, contact factory.
Operating Hours 0 25,000 50,000 100,000
Lumen Maintenance
Factor
1.0 0.94 0.90 0.80
LEGEND
(% Max cd)
10%
20%
30%
40%
50%
60%
75%
90%
Test No. LTL22174 tested in accordance with
IESNA LM-79-08.
Test No. LTL22173 tested in accordance with
IESNA LM-79-08.
Test No. LTL22153 tested in accordance with
IESNA LM-79-08.
Test No. LTL22159 tested in accordance with
IESNA LM-79-08.
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
MSP
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
WFL
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
FL
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
HMF
Mounting, Options and Accessories
THK - Knuckle with 1/2” NPS
threaded pipe
UBV – Upper/bottom visor
W= 5-1/4” (13.3 cm)
H= 2-1/2” (6.3 cm)
D= 3” (7.6 cm)
FV – Full visor
W= 5-1/4” (13.3 cm)
H= 2-1/2” (6.3 cm)
D= 3” (7.6 cm)
VG – Vandal guard
W= 6-1/2” (16.5 cm)
H= 4” (10.1 cm)
IS – Integral sliptter
H= 2-1/2” (6.3 cm)
ID= 2-3/8” (6.0 cm)
OD= 3-1/2” (8.8 cm)
H
ID
OD
H
W
D
H
W
D
W
H
DSXF1-LED
Rev. 10/02/14