Specification Sheet

To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s D-Series Flood Size 2 homepage.
Photometric Diagrams
One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com
© 2012-2016 Acuity Brands Lighting, Inc. All rights reserved.
Isocandela plots for the DSXF2 LED P2 40K.
LEGEND
(% Max cd)
10%
20%
30%
40%
50%
60%
75%
90%
Test No. ISF 31597P5 tested in accordance
with IESNA LM-79-08.
Test No. ISF 31606P5 tested in accordance
with IESNA LM-79-08.
Test No. ISF 31669P5 tested in accordance
with IESNA LM-79-08.
Test No. ISF 31614P5 tested in accordance
with IESNA LM-79-08.
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
MSP
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
WFL
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
FL
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
HMF
Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown,
within the tolerances allowed by Lighting Facts. Actual performance may differ as a result of
end-user environment and application. Actual wattage may differ by +/- 8% when operating between 120-480V +/- 10%. Contact factory for performance data
on any configurations not shown here.
Performance Data
Lumen Output
Current (A)
Light
Engines
System
Watts*
120 208 240 277 347 480
P1 54W 0.45 0.26 0.23 0.2 0.16 0.13
P2 78W 0.65 0.37 0.33 0.29 0.23 0.18
P3
102W
0.88 0.49 0.43 0.39 0.31 0.23
* Systems Watts for 347-480V; P1: 56W, P2: 80W, P3:103W.
Electrical Load
Use these factors to determine relative lumen output for
average ambient temperatures from 0-40°C (32-104°F).
Lumen Ambient Temperature
(LAT) Multipliers
Ambient
0°C 32°F
10°C 50°F
20°C 68°F
25°C 77°F
30°C 86°F
40°C 104°F
Projected LED Lumen Maintenance
Data references the extrapolated performance projections for
the DSXF LED P3 platform noted in a 25C ambient, based on
10,000 hours of LED testing (tested per IESNA LM-80-08 and
projected per IESNA TM-21-11).
To calculate LLF, use the lumen maintenance factor that
corresponds to the desired number of operating hours below.
For other lumen maintenance values, contact factory.
Operating Hours 0 25,000 50,000 100,000
Lumen Maintenance
Factor
1.0 0.95 0.95 0.95
DSXF2-LED
Rev. 11/14/16
Performance
Package
System
Watts
Dist.
Type
Field
Angle
Beam
Angle
30K
(3000K, 70 CRI)
40K
(4000K, 70 CRI)
50K
(5000K, 70 CRI)
°H °V °H °V Max Cd Lumens LPW Max Cd Lumens LPW Max Cd Lumens LPW
P1 54W
NSP
39 39 19 18 43,427 7,338 136 45,662 7,715 143 45,662 7,715 143
MSP
52 51 28 28 26,563 7,010 130 27,930 7,371 137 27,930 7,371 137
MFL
59 59 45 46 11,831 7,058 131 12,440 7,421 137 12,440 7,421 137
FL
87 87 62 68 6,258 7,309 135 6,581 7,686 142 6,581 7,686 142
WFL
114 101 87 83 3,991 7,413 137 4,197 7,794 144 4,197 7,794 144
WFR
107 92 81 71 4,827 7,429 138 5,076 7,811 145 5,076 7,811 145
HMF
123 64 89 50 6,580 6,765 125 6,919 7,113 132 6,919 7,113 132
P2 78W
NSP
39 39 19 18 59,506 10,054 129 62,568 10,572 136 62,568 10,572 136
MSP
52 51 28 28 36,397 9,606 123 38,271 10,100 129 38,271 10,100 129
MFL
59 59 45 46 16,211 9,671 124 17,046 10,169 130 17,046 10,169 130
FL
87 87 62 68 8,575 10,017 128 9,017 10,532 135 9,017 10,532 135
WFL
114 101 87 83 5,469 10,157 130 5,751 10,680 137 5,751 10,680 137
WFR
107 92 81 71 6,615 10,179 131 6,955 10,703 137 6,955 10,701 137
HMF
123 64 89 50 9,017 9,269 119 9,481 9,746 125 9,481 9,746 125
P3 102W
NSP
39 39 19 18 70,481 11,909 117 74,109 12,522 123 74,109 12,522 123
MSP
52 51 28 28 43,111 11,377 112 45,330 11,963 117 45,330 11,963 117
MFL
59 59 45 46 19,011 11,342 111 20,190 12,045 118 20,190 12,049 118
FL
87 87 62 68 10,157 11,864 116 10,680 12,474 122 10,680 12,475 122
WFL
114 101 87 83 6,198 11,510 113 6,811 12,650 124 6,811 12,650 124
WFR
107 92 81 71 7,835 12,056 118 8,238 12,677 124 8,238 12,677 124
HMF
123 64 89 50 10,680 10,979 108 11,230 11,544 113 11,230 11,544 113
Test No. ISF 31634P5 tested in accordance
with IESNA LM-79-08.
Test No. ISF 31633P5 tested in accordance
with IESNA LM-79-08.
Test No. ISF 31605P5 tested in accordance
with IESNA LM-79-08.
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
NSP
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
MFL
0°
20°
40°
60°
80°
-20°-40°-60°
-80°
0°
20°
40°
60°
80°
-20°
-40°
-60°
-80°
WFR