Trouble Shooting Guide
If this xture fails to operate properly, use the guide below
to diagnose and correct the problem.
 Verify that xture is wired properly.
 Verify that xture is grounded correctly.
 The line voltage at the xture is correct.
If further assistance is required, contact:
Technical Support at: (800) 748-5070
This LED light provides low maintenance service with no
bulbs to change.
Cleaning Diffuser: For best results, diffusers should be
washed with soap or mild detergent. Rinse with clear water
and allow to air dry.
This xture is designed for indoor use ONLY
and should not be used in areas with limited
ventilation or high ambient temperatures.
This xture is intended to be connected to a
properly installed and grounded UL listed
junction box (not provided) and should be
installed according to NEC and local building
codes.
Fixture must be secured to mounting surface with
mounting hardware appropriate to your application.
1. Remove xture components and parts pack(s). Check that
all parts are included. See Page 2.
2. Remove (2) screws (4) securing the wireway cover (2) to
the Fixture Housing (1) See Figure 1.
3. Remove 7/8” knockout at center of xture by placing straight
blade screwdriver on knockout and striking sharply with
hammer (Always wear safety glasses when hammering).
Remove slug by exing back and forth with pliers. See
Figure 2.
WARNING: Before wiring xture to the power supply, turn o
electricity at fuse or circuit breaker box. Fixture must be ground-
ed to avoid potential electrical shock and to ensure reliable lamp
starting.
4. With power turned o, lift xture housing to ceiling, center-
ing over outlet box and parallel to walls. Mark ceiling with
pencil for mounting holes through (2) 1/4” x 3/8” slots. Drill
1/8” pilot hole at each location.
If drill encounters ceiling joist, hold xture up to outlet box and
pull electrical supply wires into xture through the knockout hole,
use wood screw at each end of the xture body to secure to
ceilingjoist. See Figure 4.
If drill does not encounter ceiling joist, enlarge hole in ceiling to
accommodate toggle bolt. Hold xture up to outlet box and pull
electrical supply wires into the xture through the knockout hole,
insert and tighten toggle bolts.
See Figure 3.
5. Ground xture as follows. Connect the green or bare copper
ground wire from the outlet box under the green ground
screw. If house wiring includes no ground wire, consult your
local electrical code for approved methods. See Figure 5.
6. Connect white xture wire(s) to white power supply wire with
wirenut. Connect black xture wire(s) to black power supply
wire with wirenut.
FOR PROPER CONNECTION, PLACE WIRENUT
OVER WIRES, TWIST CLOCKWISE UNTIL TIGHT.
Note: Make sure no wires are exposed.
7. Replace wireway cover under tabs on one side of xture
housing. Make sure wires are not pinched between xture
housing and wireway cover. Secure ends of wireway cover
with screws.
8. To install diuser, lift one side of diuser almost to ceiling.
Position one side of diuser over side ange on xture
housing. Lift and shift opposite side of diuser upward and
towards xture housing until diuser rests on side ange.
9. Turn on electricity at fuse or circuit breaker box.
Page 3
Fixtures that can be used with a dimmer switch. SEE LIST ON PAGE 1
The xtures are designed to operate with most standard Triac Based
(Forward Phase-Control or Leading Edge) dimmer are not compatible
with 0-10V dimming systems.
NOTED below is a listed of dimmers that have been tested with this
xture. This list of dimmers does not imply any guarantee or warranty
of compatibility with a particular application.
Dimmers that are not listed do not imply non-compatibility.
Suggested Dimmers
Lutron: DVELV 300P, Skylark 300P, NTELV 300, NLV 600