Installation Guide
page 6
FIGURE 4: TO SEMI-FLUSH MOUNT FIXTURE
Follow steps 5B to 11B.
5B. Pre-assemble the three spacer pipes by threading a
1/8IP x 3/8" nipple into both ends of each pipe about ¼".
See Figure 5.
6B. Insert each assembled pipe into one of three outer holes
of one canopy, place a lock washer and hexnut onto each
nipple and tighten. Repeat assembly using other canopy.
See Figure 5.
7B. Gather the black, white and fixture wires together and
feed them through one of the spacer pipes. Feed the green
ground wire through another spacer pipe until the lower
canopy rests on the pan.
8B. Thread a finial cap onto the remaining 1/8IP x 1-3/8"
nipple. Push the nipple through the center holes of the
canopy and pan then secure the components with a lock
washer and hexnut. See Figure 5.
9B.With the power off, hold the fixture firmly and connect the
ground wire from the fixture to the junction box, by wrapping
them under the head of the green ground screw and secur-
ing them to the crossbar. (If house wiring includes no ground
wire consult your local electrical code for approved meth-
ods). See Figure 3.
10B.
Use wirenuts to connect the black fixture wire(s) to the
black power supply wire and white fixture wire(s) to white
power supply wire. See Figure 3 .
FOR PROPER CONNECTION, PLACE WIRENUT OVER
WIRES, TWIST CLOCKWISE UNTIL TIGHT.
11B. Place upper canopy over the nipple extending from the
crossbar previously mounted to the junction box and thread a
finial cap in place until the canopy is secure.
12. Insert the lamps(s) and reinstall the diffuser, metal ring , “L”
angles and finial caps.
13. Turn on electricity at fuse or circuit breaker box .
WIRING AND FIXTURE OPERATION
CAUTION: Connect fixture to supply wires rated for at least 90°
(194°F). Do not use fixture on dimming circuits.
Figure 5
Figure 4