INSTALLATION
INSTRUCTIONS
RISK OF FIRE - Lamps are hot. Keep
combustible material away from hot
parts.
TROUBLESHOOTING
CAUTION
If this fixture fails to operate properly, check to
make sure:
The correct lamp is properly installed.
The fixture is wired correctly.
The lamp is not faulty.
The fixture is grounded correctly.
The line voltage at the fixture is correct.
Observe lamp manufacturer's recommendations
and restrictions on lamp operations, including but
not limited to ballast type, burning position, and
cycling. Use ANSI rated lamps only.
Maintenance: For optimum performance,
periodically clean reflector and lens with a soft,
damp cloth.
Important: DO NOT use abrasive materials, glass
cleaner or other solvents on lens or paint. Use only
mild, soapy water.
WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH,
INJURY, OR SIGNIFICANT PROPERTY DAMAGE
- For your protection, read and follow these warnings
and instructions carefully before installing or maintaining this fixture. These instructions do not attempt to
cover all installation and maintenance situations. If you do not understand these instructions or additional
information is required, contact Lithonia Lighting or your local Lithonia Lighting distributor.
WARNING: RISK OF ELECTRIC SHOCK - To avoid electric shock, serious injury, or death, be certain that
all electrical power is disconnected from the supply branch circuit conductors before installing or main-
taining this fixture. This product must be installed and maintained in accordance with the applicable instal-
lation codes by a person familiar with the construction and operation of the product and the hazards
involved.
WARNING: RISK OF PERSONAL INJURY - This product may have sharp edges. Wear gloves to
prevent cuts or abrasions when removing from carton, handling, installing and maintaining this product.
Lithonia Lighting assumes no responsibility for claims arising out of improper or careless installation or
handling of this product.
IMPORIMPOR
IMPORIMPOR
IMPOR
TT
TT
T
ANT SAFETY INSTRUCTIONSANT SAFETY INSTRUCTIONS
ANT SAFETY INSTRUCTIONSANT SAFETY INSTRUCTIONS
ANT SAFETY INSTRUCTIONS
RISK OF FIRE - Observe lamp
manufacturer’s warnings, recommenda-
tions and restrictions on lamp operation
and maintenance.
WARNINGWARNING
WARNINGWARNING
WARNING
Do not install a damaged fixture.
• This fixture must be wired in accordance
with the National Electrical Code and
applicable local codes and ordinances.
Proper grounding is required to ensure
personal safety. Be certain green lead
from the fixture is connected to supply
ground.
Use code compliant connectors for all
electrical connections.
ALL work should be done by a qualified
electrician.
WARNING: NEVER connect or disconnect
any component while power supply is
engaged.
DELIVERY: Upon receipt of fixture and accesso-
ries (packed separately), thoroughly inspect for
any freight damage. All damage should be
reported to the delivery carrier. Do not install
damaged fixtures. Compare the catalog de-
scription listed on the packing slip with the fix-
ture label on the inside of the housing to be sure
you have received the correct merchandise.
IMPORTANT SAFETY
INSTRUCTIONS
WARNINGWARNING
WARNINGWARNING
WARNING
Landscape Fluorescent Flood
Prior to Installation
Read carefully before installing light fixtures. If you do not understand these instructions, please contact your
local Lithonia distributor before installing. Make sure your materials and installation meet local electrical codes.
Install only on GFCI protected circuit. Use silicone tape on all threaded parts to seal water out. Use only
approved rigid metal conduit fitting and parts suitable for outdoor and wet location use.
WIRING
Caution: TURN OFF POWER AT CIRCUIT BREAKER. Check that voltage is compatible with fixture (120V).
Use UL approved connectors for all electrical connections. Insulate all unused leads.
1. Connect the desired voltage lead from the fixture to the same voltage supply lead.
2. Connect the lead from the fixture labeled (COM) to the Common supply lead.
3. Connect the ground wire (green or bare copper wire) from the fixture lead to the ground supply lead.
LAMP INSTALLATION AND RE-LAMPING
1. When lamping, turn power off at the circuit breaker and allow the fixture to cool adequately.
2. Prior to installing the lamp in the fixture, check to be sure the lamp is of proper type and wattage.
3. Remove the lens by loosening the 4 captive screws.
4. Line up the pins at the base of the lamp(s) with the 4 holes in the socket.
5. Snap the lamp securely into the socket.
6. Reinstall the lens being careful not to overtighten.
7. Restore power.
INSTALLATION
LOCATION: Landscape fluorescent flood can be mounted on standard 1/2" conduit. This fixture should not
be mounted within 6” of any flammable materials. This fixture is for outdoor use and should not be used in
areas with limited ventilation or high ambient temperatures. Fixture should not be recessed.
MOUNTING
1. Screw 1/2" threaded fixture arm into threaded, UL approved, waterproof opening.
AIMING: Loosen the side bolt connected to the arm knuckle to aim the fixture up or down. Re-tighten bolt to
secure the fixture in the desired position.