Installation Instructions

®
SPECIFICATIONS
ORDERING INFO
OPTIONS
LOW VOLTAGE RELAY (R)
Enables sensors to interface with
other systems (e.g., BMS, lighting
panels)
Provides dry contact closure via a
SPDT, 1 Amp, 40 Volt relay
Only one relay needed per zone
Changes state when all connected
sensors register unoccupied
Relay requires sensor power to
function
PHOTOCELL (P)
Auto set-point calibration
Two selectable modes of operation
On/Off mode: Photocell has full control
during periods of occupancy
Inhibit mode: Photocell can prevent
lights from turning on if adequate
daylight is available, but cannot turn
lights off
LOW TEMP/HIGH HUMIDITY (LT)
Sensor electronics are coated for
corrosion resistance
Operates down to -40º F/C
OVERVIEW
Long narrow PIR detection for control of hallway
lighting is provided by the HW13 Series sensor.
Applied in pairs and mounted at either end of
a long corridor, the HW13 detects occupants
entering the hallway up to 130 ft (39.62 m) away
(when mounted at 10 ft (3.05 m)). Detection at
these distances is for entrances at right angles to
the beam pattern. The HW13 may also be used
with other low voltage sensors to adequately
view a space. For example, a CM 10 ceiling
sensor may be in a vestibule at one end while
the HW13 is at the other. The HW13 is best
mounted at 7 ft (2.13 m).
SENSOR OPERATION
The sensor detects changes in the infrared
energy given off by occupants as they move
within the eld-of-view. When occupancy is
detected, a DC output goes high and can
drive up to 200 mA of connected load. The
sensor is powered with 12-24 VAC/VDC and
typically operates with a PP20 or MP20 power
pack, enabling complete 20 Amp circuits to be
controlled. This innovative sensor requires no
eld calibration or sensitivity adjustments.
LAMPMAXIMIZER
®
This sensor also contains patented
LampMaximizer technology that allows users
to aggressively target energy savings while still
protecting lamp life. A minimum on timer, factory
set at 15 minutes, helps preserve lamp life by
eliminating all lamp cycles shorter than lamp
manufacturers’ recommendations.
A standard occupancy time delay is also present
that ensures lights turn off (assuming minimum
on timer has elapsed) if no occupancy is
detected. This timer is factory set at 10 minutes
to promote energy savings, but is adjustable
between 30 seconds and 20 minutes. These
adjustments can be done manually, through
the units push-button, or automatically every
two weeks through an advanced mode, called
LampMaximizer+, that determines the optimum
time delay in order to maximize both lamp life
and energy savings. Additionally, this sensor
maintains statistics on total lamp on time and
number of cycles.
HALLWAY SENSOR
WALL MOUNT • LOW VOLTAGE • PASSIVE INFRARED (PIR)
HW13
FEATURES
100% Digital PIR Detection,
Excellent RF Immunity
Coverage up to 130 ft (39.62 m)
when mounted at 10 ft (3.05 m)
Push-Button Programmable
Adjustable Time Delays
Convenient Test Mode
No Field Calibration or Sensitivity
Adjustments Required
100 hr Lamp Burn-in Timer
Green LED Indicator
LAMPMAXIMIZER
®
TECHNOLOGY
Protects Lamp Life while
Maximizing Energy Savings
Minimum On Timer (15 min default)
Occ. Time Delay (10 min defatult)
LampMaximizer+ Mode -
Optimizes Lamp Life & Energy
Savings (disabled by default)
Switch Counter (in 1000’s)
Total Lamp On Time (in khrs)
PHYSICAL SPECS
SIZE 3.0” H x 3.6” W x 1.75” D
(7.62 cm x 9.14 cm x 4.45 cm)
WEIGHT 5 oz
MOUNTING Directly to wall or to
ceiling using WV BR bracket
COLOR White
ELECTRICAL SPECS
OPERATING VOLTAGE
12-24 VAC/ VDC
CURRENT DRAW
Standard, 4 mA
w/ R option, 16 mA
RECOMMENDED POWER PACK
PP20
ENVIRONMENTAL SPECS
OPERATING TEMP
14º to 160º F (-10º to 71º C)
RELATIVE HUMIDITY
20 to 90% non-condensing
SILICONE FREE
ROHS COMPLIANT
RELAY
HW13 [RELAY] [PHOTOCELL] [TEMP/HUMIDITY]
Blank = None Blank = None Blank = Standard
R = Low Voltage Relay P = Photocell LT = Low Temp
TEMP/HUMIDITY
PHOTOCELL
C US LISTED
TITLE 24
ASSEMBLED in U.S.A.
5 YEAR WARRANTY

Summary of content (2 pages)