Installation Guide
Installation Instructions
Lithonia Lighting
INDUSTRIAL VALUE STREAM
One Lithonia Way, Conyers, GA 30012
Phone: 800-315-4963 Fax: 770-981-8141
www.lithonia.com
Part Number: U217803
Revision Date: 12/10/07
L / LA STANDARD INDUSTRIALS
L LA STANDARD INDUSTRIAL INSTRUCTION SHEET
FIXTURE COMPONENT VERIFICATION (STANDARD 4 FOOT FIXTURE)
Remove the channel and reflector from the carton
Identify that you have:
2 End plates
2 Reflector aligners (required if doing tandem installation or CRM installation)
1 Pre-pack containing the two (2) ¼-turn fasteners
1 Channel with ballast and sockets
1 Reflector
SOCKET INSTALLATION
1. Extend wire with socket to appropriate end of fixture per wiring diagram located on the ballast label.
2. Slide socket with wires under socket bracket to the outside of the channel.
3. Slide each socket onto the socket bracket on each end of the channel. (T8 sockets shown)
4. Ensure sockets are secured and in the locked position. (For T5 fixtures, sockets snap in from the underneath
the socket bracket. Push the T5 sockets though the rectangle slot until the socket snaps into place).
STANDARD END PLATE INSTALLATION (Not for CRM –continuous row mounting)
1. Align tabs on the end plate with the lances (slots) on each side of the channel.
2. Push the end plate into the channel opening. The end plate tabs should lock in place with the lances on
either side of the channel.
MOUNTING FIXTURE
1. Use the mounting option that is best suited for your individual application. i.e. Surface or Suspended Mounting.