KNOCK OUT REMOVAL
Determine where power supply will be entering the fixture. (i.e. side, end, or back of channel). Remove appropriate
knock out best suited for the incoming supply wires.
WIRING OF FIXTURE
1. Wire fixture according to your local electrical code. Insulate all unused fixture wires individually using approved
electrical wire nuts (not provided). Wire Black wire of fixture to Black supply wire, White wire of fixture to White
supply wire and Ground wire to Ground screw or ground wire.
INSTALLATION OF REFLECTOR
1. Remove the 2 (two) ¼ turn fasteners from the prepack.
2. Place reflector on the channel.
3. Insert one ¼-turn fastener into the hole on one end of reflector.
4. Rotate ¼ of a turn and lock in place.
5. Repeat steps 3 and 4 for the opposite end of the reflector.
Step 3
Step 4
TANDEM or CRM (continuous row mounting) REFLECTOR ALIGNMENT
1. Slide or push aligner onto both sides of the end of the reflector, where the second reflector will join with the
first reflector.