Cut Sheet
LBR6
6" OPEN
FEATURES & SPECIFICATIONS
INTENDED USE — Typical applications include corridors, lobbies, conference rooms and private oces.
CONSTRUCTION — Retrot, remodel, and new construction mounting types. See table for compatible
ceiling openings and thickness range.
Optional goof rings available for additional overlap trim coverage.
1/2"-1-1/2" ceiling thickness
25° ambient temperature
IC rated up to 1000lm
OPTICS — 55° cuto
New construction frame accessories approved for 8 (4 in/4 out) No. 12 AWG conductors rated for
90°C through wiring.
1.0 S/MH standard (wallwash reector available)
80CRI standard (90CRI optional)
ELECTRICAL — Adjustable lumen output with three module options. Fixed lumen options also available.
MVOLT 120/277V 50/60Hz driver (0-10V & 120V Phase Dimming to 10% or 1% min dimming level)
100LPW typical
FCC CFR Title 47 Part 15 Class A for 277V. FCC CFR Title 47 Part 15 Class B for 120V.
L80 at 60,000 hours
3 SDCM
LISTINGS — Certied to US and Canadian safety standards. Damp location standard (Wet location,
covered ceiling optional). Some congurations are ENERGY STAR® certied, please visit www.energystar.
gov for specic products. TAA compliant. UFC (3-530 -01) specication compliant for power factor and THD.
GSA P100 6.2.4 compliant for power quality at full output; compliant up to 2000lm at fully dimmed output.
Title 24 compliant (90CRI, up to 1000lm).
WARRANTY — 5-year limited warranty. This is the only warranty provided and no other statements
in this specication sheet create any warranty of any kind. All other express and implied warranties are
disclaimed. Complete warranty terms located at:
www.acuitybrands.com/support/warranty/terms-and-conditions
Note: Actual performance may dier as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
Specications subject to change without notice.
ORDERING INFORMATION
Example: LBR6 ALO2 SWW1 AR LSS MWD MVOLT UGZ 90CRI
Lead times will vary depending on options selected. Consult with your sales representative.
Series Lumens ‡ Color temperature ‡ Reector Color Reector Flange Reector Finish
LBR6 6" Retrot
LBR6WW 6" Retrot Wallwash
Adjustable Lumen Output
ALO1 500/750/1000lm
ALO2 1000/1500/2000lm
ALO3 2000/2500/3000lm
ALO4 4000/4500/5000lm
Fixed Lumen Output
05LM 500lm
07LM 750lm
10LM 1000lm
15LM 1500lm
20LM 2000lm
25LM 2500lm
30LM 3000lm
40LM 4000lm
45LM 4500lm
50LM 5000lm
Switchable CCT
SWW1 3000K-3500K-
4000K-5000K
Fixed CCT
30K 3000K
35K 3500K
40K 4000K
50K 5000K
AR Clear
WR ‡ White painted
BR ‡ Black painted
(blank) Self-anged
TRW ‡ White
painted
ange
TRBL ‡ Black
painted
ange
LSS Semi-specular
Distribution Voltage Driver Options
MWD Medium wide
(1.0 s/mh)
WD Wide
(1.2s/mh)
WW ‡ Wallwash
MVOLT
120
277
347
UGZ Universal dimming to 10%
0-10V; line voltage dimming (120V)
UGZ1 Universal dimming to 1% 0-10V; line
voltage dimming (120V)
DALI ‡ DALI dimming to 1%
D10 Minimum dimming 10% driver for use
with JOT
D1 Minimum dimming 1% driver for use
with JOT
90CRI High CRI (90+)
AT ‡ Airtight
E10WCP ‡ Batterypack (10W constant power)
Non-T20 Compliant integral test switch
E10WCPR ‡ Batterypack (10W constant power) T20
Compliant remote test switch
ELR ‡ Batterypack (10W constant power)
Non-T20 Compliant remote test switch
ETS ‡ Iota Emergency Transfer System
EC1 ‡ Extended Conduit (18")
EC6 ‡ Extended Conduit (6ft)
WL ‡ Wet Location (IP55)
QDS ‡ Quick disconnect plugs
CP ‡ Chicago Plenum
JOT ‡ Wireless room control with “Just
One Touch” pairing
Catalog
Number
Notes
Type
D
I
M
M
A
B
L
E
A+ Capable options indicated
by this color background.
battery pack
DOWNLIGHTING
LBR6
Retrot | Remodel
CAN BE USED TO
COMPLY WITH 2019
JA8 HIGH EFFICACY LED LIGHT
SOURCE REQUIREMENTS
New Construction Frames: Order as separate catalog number. Shipped separately.
LBR6PFW 6" New construction frame with JBOX, 18" conduit
LBR6PFWQDS 6" New construction frame with JBOX, 18" conduit, quick disconnects
LBR6PFWCP 6" Chicago Plenum New construction frame with JBOX, 18" conduit
Module ordering
NOTE: ‡ indicates option value has ordering restrictions. Please reference the Option Value Ordering
Restictions chart on the next page.
nLight Options ‡
NPS80EZ nLight® network power/relay pack with 0-10V dimming
NPS80EZER nLight® network power/relay pack with 0-10V dimming; ER controls xtures on emergency circuit.
NLTAIR2 nLight® Air enabled
NLTAIRER2 nLight® AIR Dimming Pack Wireless Controls. Controls xtures on emergency circuit
NLTAIREM2 nLight® AIR Dimming Pack Wireless Controls. UL924 Emergency Operation, via power
interrupt detection.
New Construction