Specification

Catalog Number
Notes Type
FEATURES & SPECIFICATIONS
INTENDED USE
Ideal for a wide variety of low- to medium-height ceiling applications
including commercial, retail and hospitality spaces where a baffled fix-
ture is required.
CONSTRUCTION
Heavy gauge die formed galvanized steel mounting frame. Attached to
frame are vertically adjustable mounting brackets for use with C channels,
½” steel conduit or 16 gauge flat bar hangers included, standard. Frames
equipped with galvanized junction box UL Listed for through wire applica-
tions. Junction boxes equipped with (2) ¾” and (4) ½” conduit knockouts with
pryout slots and removable access doors.
Maximum 1-1/2" ceiling thickness.
OPTICS
Aluminum full reflectors are optically designed to maximize lumen output and
to provide superior glare control. The black or white baffled reflectors have
a semi-specular upper finish with white painted flange standard.
ELECTRICAL
Electronic ballast with end of lamp life protection standard. Class P thermally
protected ballast protects against improper contact with insulation. Mini-
mum starting temperature is 0°F/-18°C.
Rated for #12 AWG conductor thru-branch wiring. Minimum 90° supply wire.
Ground wire provided.
Lamp Socket Base:
TRT 4-pin lamps – 26W (GX24Q-3); 32W (GX24Q-3); 42W (GX24Q-4)
LISTING
Fixtures are UL Listed for thru-branch wiring, Non-IC recessed mounting,
damp location, and to U.S. and Canadian Safety Standards.
Compact Fluorescent Downlighting
6” LF6N
BAFFLE
Horizontal 1-Lamp, Triple Tube (TRT)
All dimensions are inches (centimeters).
Specifications
Max. height: 6-3/8 (16.2)
Ceiling opening: 7 (17.8)
Overlap trim: 7-1/2 (19.1)
Length: 13 (33.0)
Width: 11 (27.9)
Series
LF6N
LF6N
Wattage/lamp
1/18DT/TRT
1/26-42TRT
1
1/26TRT
1/32TRT
1/42TRT
NOTES:
1 Not available with DMHL or WLP.
2 White painted flange standard.
3 Electronic multi-volt ballast capable of operating
any line voltage from 120-277V, 50 or 60Hz.
4 Not available with EL or ELR.
5 Add 3” (7.6) to width and 4-1/2” (11.4) to length.
6 Not recommended for field installation.
Downlighting and Track Sheet #: LF6N-BAFFLE-1-TRT
For shortest lead times, configure product using standard options (shown in bold).
Example: LF6N 1/26-42TRT F6B5 MVOLT
ORDERING INFORMATION
Accessories
Order as separate catalog number
SCA6 Sloped ceiling adaptor. Degree of
slope must be specified (10D, 15D, 20D,
25D, 30D) Ex: SCA6 10D.
CTE6 Ceiling thickness extender is used
when ceiling thickness is greater than
1-1/2 (3.8). Maximum thickness 2 (5.1).
Reflector/color
2
F6B5 Black baffle
F6B5W White baffle
Voltage
MVOLT
3
120
277
347
4
Options
ADEZ Advance Mark 10™ electronic dimming ballast, 120V
or 277V. Musts be voltage specific. Minimum
dimming level 5%
DMHL Lutron Compact SE™ electronic dimming ballast,
120V or 277V. Must be wattage and voltage specific.
Minimum dimming level 5%
EL Emergency PSDL3 DL battery pack with integral
test switch.
5
ELR Emergency PSDL3 DL battery pack with remote
test switch
5
ELHL Iota I-420-R High lumen output emergency battery
pack. Internal test switch provided. Maximum average
lumen output is 1300 (42W)
6
ELRHL Iota I-420-EM-B High lumen output emergency
battery pack. Remote test switch provided.
Maximum average lumen output is 1300 (42W)
6
GMF Single slow-blow fuse, must specify voltage
BDP Ballast disconnect plug (meets codes that require
in-fixture disconnect)
4
RIF1 Radio interference filter
LBH Less barhangers
WLP 35K lamp (shipped separately)
6-3/8
(16.2)
7-1/2
(19.1)
11
(27.9)
13
(33.0)
6-3/8
(16.2)
6
(15.2)
7-1/2
(19.1)

Summary of content (2 pages)