Top Mount:
1. Connect jumper leads (provided) to AC input
leads in j-box. Fasten j-box bracket.
NOTE: Max mounting height is 9 ft to achieve at least 1 ft-candle of illuminance in emergency mode.
2. Fasten canopy to j-box bracket. Remove
face plate from housing. Remove hole plug
and dress leads through housing wire chan-
nel. Snap exit housing onto canopy.
3. Remove necessary knockouts and fasten
back plate to j-box.
4. Snap housing to back plate.
Back Mount:
1. Connect installation supply leads (provided)
to AC input leads in j-box. Remove face plate
and back plate from housing.
To Install Canopy-Locking Pin:
Lay cam locking pin between canopy posts and
snap into retaining hooks. Rotate cam locking pin
up to lock into place.
To Remove Back Plate:
2. Press in and release snaps at bottom or top
of housing. Then release two latches from the
inside of housing.
Remove and Relocate Lamp
Mount Assembly:
Disconnect lamp harness from lamp
board. Press four snaps (two each
side) to release lamp mount assem-
bly from housing. Relocate to top
of housing and re-snap into place.
Connect lamp harness to lamp board.
5. Route wires through upper wireway. In upper
left corner of housing wire channel, trim and
connect input leads using push nuts and jumper
wire provided to route wires to j-box. Connect
battery after AC power can be continuously
provided and snap face plate onto housing.
Remote lamp option: Connect remote
lamps to yellow and blue wires using pushnuts
and jumper wire provided to route wires to j-box.
SD option: Connect remote lamps to yellow,
white and blue wires.
3. In upper left corner of housing wire channel connect
input leads using push nuts and jumper wire provided
to route wires to j-box. Connect battery after AC power
can be continuously provided to exit and snap face
plate onto housing. Remote lamp option: Connect
remote lamps to yellow and blue wires using push nuts
and jumper wire provided to route wires to j-box.