Specification
Lithonia Lighting
Recessed Downlighting and Track
One Lithonia Way, Conyers, GA 30012
Phone: 800-315-4935 Fax: 770-918-1209
www.lithonia.com
6” LP6FN Vertical 1-Lamp, Double Twin-Tube (DTT) or Triple Tube (TRT), Baffle
Sheet #: LP6FN-BAFFLE
© 2009-2011 Acuity Brands Lighting, Inc. All rights reserved. Rev. 3/7/11
Distribution Curve Distribution Data Output Data Coefficient of Utilization
LP6FN 1/32TRT 6B9 MVOLT, (1) 32W TRT lamp, 2400 rated lumens, 1.0 s/mh, Test no. LTL10731
Coefficients of Utilization
pf 20%
pc 80% 70% 50%
pw 50% 30% 50% 30% 50% 30%
RCR
0
1
2
3
4
5
6
7
8
9
10
51
46
42
38
35
32
29
27
25
23
21
51
45
40
36
32
29
26
24
22
20
18
50
46
41
38
34
31
29
26
24
23
21
50
44
39
35
32
28
26
23
21
20
18
47
44
40
37
33
31
28
26
24
22
21
47
43
38
34
31
28
25
23
21
20
18
Zonal Lumen Summary
Zone Lumens % Lamp
*
*Total Efficiency
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
341.9
525.4
752.3
769.5
0.0
769.5
19.0
29.2
41.8
42.7
0.0
42.7
Polar Plot
0° 10° 20°
30°
40°
50°
60°
70°
80°
90°
0
40
120
200
280
360
440
Intensity Distribution
Horizontal Angle
Vertical Angle 0
0
5
15
25
35
45
55
65
75
85
90
423
438
445
385
295
191
89
10
1
0
0
6B3 26TRT (1) 26W TRT lamp, 1800 rated lumens, Test no. LTL10754
LP6FN 1/42TRT 6B9 MVOLT, (1) 42W TRT lamp, 3200 rated lumens, 1.1 s/mh, Test no. LTL10719
Coefficients of Utilization
pf 20%
pc 80% 70% 50%
pw 50% 30% 50% 30% 50% 30%
RCR
0
1
2
3
4
5
6
7
8
9
10
42
38
34
31
28
25
23
21
20
18
17
42
37
32
29
25
23
20
19
17
15
14
41
37
34
30
28
25
23
21
19
18
17
41
36
32
28
25
23
20
18
17
15
14
39
36
32
29
27
24
22
20
19
18
16
39
35
31
28
25
22
20
18
17
15
14
Zonal Lumen Summary
Zone Lumens % Lamp
*
*Total Efficiency
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
345.3
540.6
798.4
841.9
0.0
841.9
14.4
22.5
33.3
35.1
0.0
35.1
Polar Plot
0° 10° 20°
30°
40°
50°
60°
70°
80°
90°
0
40
120
200
280
360
440
Intensity Distribution
Horizontal Angle
Vertical Angle 0
0
5
15
25
35
45
55
65
75
85
90
398
411
443
396
314
212
105
37
2
1
0
6B3 32TRT (1) 32W TRT lamp, 2400 rated lumens, Test no. LTL10731
Coefficients of Utilization
pf 20%
pc 80% 70% 50%
pw 50% 30% 50% 30% 50% 30%
RCR
0
1
2
3
4
5
6
7
8
9
10
38
34
30
27
24
22
20
18
17
15
14
38
33
28
25
22
19
17
16
14
13
12
37
33
30
26
24
22
20
18
17
15
14
37
32
28
24
21
19
17
16
14
13
12
36
32
29
26
23
21
19
17
16
15
14
36
31
27
24
21
19
17
15
14
13
12
Zonal Lumen Summary
Zone Lumens % Lamp
*
*Total Efficiency
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
375.8
582.7
889.2
1023.3
0.0
1023.3
11.7
18.2
27.8
32.0
0.0
32.0
Polar Plot
0° 10° 20°
30°
40°
50°
60°
70°
80°
90°
0
40
120
200
280
360
440
Intensity Distribution
Horizontal Angle
Vertical Angle 0
0
5
15
25
35
45
55
65
75
85
90
443
461
488
426
333
227
145
84
40
4
0
6B3 42TRT (1) 42W TRT lamp, 3200 rated lumens, Test no. LTL10719
LP6FN 1/26TRT 6B9 MVOLT, (1) 26W TRT lamp, 1800 rated lumens, 1.0 s/mh, Test no. LTL10754