Specification
TFX2 LED
Rev. 12/03/19
Page 2 of 2
One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.acuitybrands.com
© 2019 Acuity Brands Lighting, Inc. All rights reserved.
COMMERCIAL OUTDOOR
Pole/Mounting Information
Accessories including bullhorns, cross arms and other adapters
are available under the accessories tab at Lithonia’s Outdoor
Poles and Arms product page.Click here to visit Accessories.
To see complete photometric reports or download
.ies files for this product, visit Lithonia Lighting’s.
Photometric Diagrams
Distances are in units of mounting height (25’).
LEGEND
0.1 fc
0.2 fc
1.0 fc
0.5 fc
Luminaires tilted at 45˚
Visual - Template Tool
These lighting calculation results are for general informational purposes only and are provided without warranty as to accuracy, completeness, reliability or
otherwise. Results are based on user provided data and data provided from publicly available sources; actual field conditions may affect calculated output. Visit
www.Visual-3D.com .
Design Information
Project
Description
Thursday, March 21, 2019
Name
Company
Phone
Email
[ A ] -
Manufacturer Caster Configuration Single
Lamp Lumens 12827 Orientation Single
Lamp Quantity 1 Mounting Height 25
Light Loss Factor 1 Arm Length 1
Input Power 93.1 Tilt 45
Max Illuminance 5 Area > 0.5fc 4414
Page 1 of 1Template Print
3
/
21
/
201
9
http://www.visua
l
-3d.com/tools/template/Print.aspx?SessionID=867793
4
7
6
5
4
3
2
1
0
-1
-2
-3
-4
-5
-6
-7
7 06 5 4 3 2 1 1 2 3 4 5 6 7
TFX2 - Luminaire EPA
TFX2 LED
Angle of Tilt EPA (ft2)
0° 0.62
10° 0.64
20° 0.76
30° 0.87
40° 0.96
50° 1.02
60° 1.07
70° 1.08
80° 1.10
90° 1.12
*Includes luminaire and integral mounting arm.
Other tenons, arms, brackets or other accessories
are not included in this EPA data.
Performance Data
Lumen Ambient Temperature
(LAT) Multipliers
Use these factors to determine relative lumen
output for average ambient temperatures from
0-50°C (32-122°F).
Ambient Ambient Lumen Multiplier
0°C 32°F 1.05
5°C 41°F 1.04
10°C 50°F 1.03
15°C 59°F 1.02
20°C 68°F 1.01
25°C 77°F 1.00
30°C 86°F 0.99
35°C 95°F 0.98
40°C 104°F 0.97
45°C 113°F 0.96
50°C 122°F 0.95
Luminaire Input Power (W) 120V 208V 240V 277V
TFX2 LED
Input Current
(Amperes)
94W 0.78 0.45 0.39 0.34
Electrical Load (Amperage)
Values calculated according to IESNA TM-21-11 methodology and valid up to 40°C.
Operating Hours 50,000 75,000 100,000
Lumen Maintenance Factor >0.94 >0.91 >0.90
Projected Lumen Maintenance
Data references the extrapolated performance projections in a 25°C
ambient, based on 6,000 hours of LED testing (tested per IESNA LM-80-08
and projected per IESNA TM-21-11).
To calculate LLF, use the lumen maintenance factor that corresponds to the
desired number of operating hours below. For other lumen maintenance
values, contact factory.
TFX2 with Knuckle Mount TFX2 with Yoke Mount
14-7/8” [38cm]
17-3/4” [45cm]
10-1/8” [26cm]
8-1/2” [21.5cm]
4-3/4” [12cm]
14-7/8” [38cm]
14-1/2” [37cm]
10-1/8” [26cm]
5-1/4” [13.5cm]
4-3/4” [12cm]
Power wire length
30” [80cm]
Electrical and Lumen Maintenance Data
Product Dimensions
Weight: 14lbs (6.4kg)