Installation Guide

Installation Instructions
TWP-LED
Part Number: RJ521354 Rev A
Revision Date: 11-19-12
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 800-279-8041 • Fax: 770.918.1209 •
www.lithonia.com
© 2011 Acuity Brands Lighting, Inc. All rights reserved. 11/12
Wire Guard
WALL MOUNT:
1. Drill wall in two places for two
(2) 10-24 fasteners (not provided)
per drilling detail (Figure D).
2. Place wire guard over fi xture.
3. Secure in place with fasteners
from step 1.
Figure D
FIXTURE MOUNT:
1. Drill fi xture per drilling de-
tail (Figure E). NOTE: Remove
photoelectric cell (when provided)
before drilling for fi xture mounted
wire guard.
2. Place wire guard over fi xture.
3. Secure in place with two (2) 10-
24 fasteners, washers, and spacers
(provided) as shown (Figure F).
Troubleshooting: If this fi xture fails to operate properly, check to make sure: • The fi xture is wired correctly. • The fi xture is
grounded correctly. • The line voltage at the fi xture is correct. If all these variables have been checked and the fi xture still
does not operate as specifi ed, contact your local Lithonia Lighting distributor.
Figure F
TWP Back Housing
1-1/2"
18-1/2"
Drill two places
for 10-24 fasteners
(by others)
1”from
wall
7 1/2”
Figure E