Specification

Page 3 of 5
ZL1N LED Striplight
INDUSTRIAL ZL1N
PRODUCT INFORMATION
Advanced plug-in system with three-circuit capability. Available on industrial and strip products and a
variety of architectural products mounted in continuous rows. 1, 2, 3 and 4-lamp xtures. PLR22 (2-cir-
cuit) and PLR33 (3-circuit) crossover harness switches hot circuit serving next xture in row. Reduces
xture types on job for alternating circuit applications (see example below.)
Easy one-step installation, saves up to 35% on labor costs. Expanded switching exibility helps save energy.
Rows can be 50% longer with two-circuit systems. Polarized, lock-together nylon connectors prevent
miswiring in the eld. #12 THHN conductor, rated 600V, 90°C. White neutral wire included. Grounding
accomplished by xture in-row connectors.
CSA certied systems available with up to 2 circuits. G ground required.
Note: Specications subject to change without notice.
Wiring
PLR
Advanced 3-Circuit Plug-In
Typical Applications
• Multiple-circuit and single-circuit for longer continuous rows
• Multiple-circuit with alternating xtures on separate circuits,
2-circuit (PLR 22) and 3-circuit (PLR 33)
• Multiple circuit with night-lights located along row as desired
TYPICAL APPLICATIONS
PLR 3 C PLR 3 C PLR 3 C PLR 3 C PLR 2 B PLR 2 B PLR 2 B PLR 2 B PLR 1 PLR 1 PLR 1
(All PLR22)
Circuit A Circuit B Circuit A Circuit B Circuit A Circuit B Circuit A Circuit B Circuit A Circuit B Circuit A
(All PLR33)
Circuit A Circuit B Circuit C Circuit A Circuit B Circuit C Circuit A Circuit B Circuit C Circuit A Circuit B
PLR 3 A PLR 3 A PLR 3 A PLR 3 C PLR 3 B PLR 3 B PLR 3 B PLR 3 C PLR 3 A PLR 3 A PLR 3 A
Series Number of hot wires Branch circuits Dimming Ground
PLR
PLR22
PLR33
(blank) Not required for 22 or 33
1 Black
2 Black and red
3 Black, red and blue
Circuits to which ballast is connected
(blank) Not required for 22 or 33
A Black wire
B Red wire
C Blue wire
LV Low-voltage dimming (blank) No ground in PLR
G Ground. Maximum 2 circuits
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Passive Infrared Indoor Occupancy Sensor
LSXR
Single Relay
PRODUCT INFORMATION
A standard occupancy time delay is also present to ensure lights turn o (once minimum on timer has
also elapsed) if no occupancy is detected.
This timer is factory set at 10 minutes to promote energy savings, but is adjustable between 30 seconds
and 30 minutes. These adjustments may be done through the unit’s push-button.
FEATURES
• Four interchangeable lenses - high mount 360°, low mount 360°, high mount aisleway, and small
motion 360°.
• Integrated mounting bracket drops lens down 3" from chase nipple - no bracket accessory required.
• 100% digital PIR detection - provides excellent RF immunity
Note: Specications subject to change without notice.
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: LSXR 10 ADC HVOLT 30M
LSXR
Series Lens option Dimming/photocell
LSXR Passive Infrared Indoor
Occupancy Sensor
(blank) No lens
6 High mount, 360®
10 Low mount, 360°
50 High mount aisleway
9 Small motion, 360°
610 High and low mount 360°
650 High mount 360° and aisleway
3PK High and low mount 360° and aisleway
4PK All lenses
(blank) None
HL High/low occupancy operation
P Switching photocell (on/o)
ADC Dimming and switching photocell
ANL Dimming and switching photocell with
high/low occupancy operation
Voltage Max dim level Min dim level Lead length Temp humidity Default time delay
(blank) 120-277 VAC
(MVOLT)
HVOLT 347-480 VAC
(blank) 10 VDC
9H 9 VDC
8H 8 VDC
7H 7 VDC
(blank) Minimum dimming level of ballast
1V 1 VDC
2V 2 VDC
3V 3 VDC
4V 4 VDC
5V 5 VDC
6V 6 VDC
(blank) 14"
42L 42"
(blank) None
LT Low temperature
(blank) 10 minutes (with minimum
15 minutes on time)
5M 5 minutes (LED only)
15M 15 minutes
20M 20 minutes
30M 30 minutes
For additional information see www.lithonia.com