Cut Sheet

Table Of Contents
LITHONIA COMMERCIAL & INDUSTRIAL FLUORESCENT
73
www.lithonia.com | 1-800-858-7763PSG10
LOW BAY INDUSTRIALS
Series
1,4
Number of lamps
2
Lamp type
2
Voltage
UN Three or four lamps, heavy-duty strip
2UN Two lamps, heavy-duty strip
EJ Three or four lamps, solid top
EJA Three or four lamps, uplight
2EJ Two lamps, solid top
2EJA Two lamps, uplight
2
3
4
14T5 14W T5 (22")
17 17W T8 (24")
20 20W T12 (24")
21T5 21W T5 (34")
24 24W T12 slimline (24")
24HO 35W T12 800mA (24")
25 25W T8 (36")
28T5 28W T5 (46")
32 32W T8 (48")
36 36W T12 slimline (36")
36HO 45W T12 800mA (36")
48 38W T12 slimline (48")
48HO 60W T12 800mA (48")
54T5HO 54W T5HO (46")
72 55W T12 slimline (72")
72HO 85W T12 800mA (72")
96T8 96W T8 slimline (96")
96T8HO 96W T8 T8HO (96")
96HO 110W T12 800m A (96")
96VHO 210W T12 1500m A (96")
MVOLT
120
277
347
3
Ballast conguration Ballast Options
(blank) 1- and/or 2-lamp ballasts per
Lithonia Lighting standards
1/3 One 3-lamp ballast
1/4 One 4-lamp ballast
GEB10IS T8 electronic ballast, ≤10% THD,
instant start
GEB10RS T8 electronic ballast, ≤10% THD,
program rapid start
GEB10PS T5 electronic ballast, ≤10% THD,
program start
GEB T12 electronic ballast, ≤20% THD
EL14 Emergency battery pack
EL55 Emergency battery pack (nominal 350-700 lumens)
EL65 Emergency battery pack (nominal 725-1325 lumens)
GLR Internal fast-blow fusing
5,6
GMF Internal slow-blow fusing
5,6
PLF Plug-in wiring; specify 1, 2 or 3 branch circuits and hot wires (A=black, B=red, C=blue, AB or AC)
TILW Tandem in-line wiring
CSA Meets Canadian standards
NOM Meets Mexican standards
Intended Use
Use for applications requiring
high illumination in medium
to high mounting heights
and a rugged, heavy-duty
strip design.
Construction
Heavy-duty formed channel
with high-gloss, baked white
polyester nish.
EJ: Solid-top reector
or uplight is available.
Premium-gauge channel
features gripper-back design
for strength and rigidity.
Lampholders secured by
screwed-on end plates.
Heavy-duty row connector
furnished for continuous
mounting.
For wireguards and mounting
accessories, see page 93.
Electrical
Ballast: Thermally protected,
resetting, Class P, HPF, non-
PCB, UL Listed, CSA Certied
ballast is standard. Sound
rating depends on lamp/
ballast combination.
Wiring and electrical:
AWM, TFN or THHN wire
used throughout, rated for
required temperatures.
Ballast disconnect provided
standard where required
to comply with U.S. and
Canadian electrical codes.
Listings
UL Listed. CUL Listed or CSA
Certied to Canadian standards.
NOM Certied – optional.
ORDERING INFORMATION
For shortest lead times, congure products using bolded options.
Example: EJ 2 32 MVOLT GEB10IS
ADDITIONAL INFORMATION
For additional product information, visit www.lithonia.com.
CONFIGURATIONS
SERIES
LAMPS
PER CROSS
SECTION
LAMPS
PER
FIXTURE
LAMP TYPE
WIDTH: UN
IN. CM
WIDTH: EJ
IN. CM
DEPTH
IN. CM
LENGTH
IN. CM
UN, EJ 3, 4 3, 4 14T5, 17, 24, 24HO 9 (22.9) 12 (30.5) 3-3/4 (9.5) 24 (69.9)
UN, EJ 3, 4 3, 4 21T5, 25, 36, 36HO, 39HO 9 (22.9) 12 (30.5) 3-3/4 (9.5) 36 (91.4)
UN, EJ 3, 4 3, 4 28T5, 32, 48, 48HO, 54T5HO 9 (22.9) 12 (30.5) 3-3/4 (9.5) 48 (121.9)
2UN, 2EJ 2 2 28T5, 32, 48, 48HO, 54T5HO 9 (22.9) 16 (40.6) 3-3/4 (9.5) 48 (121.9)
UN, EJ 3, 4 3, 4 72, 72HO 9 (22.9) 12 (30.5) 3-3/4 (9.5) 72 (182.9)
UN, EJ 3, 4 3, 4 96HO, 96T8HO 9 (22.9) 12 (30.5) 3-3/4 (9.5) 96 (243.8)
2UN, 2EJ 2 2 96HO, 96T8HO 9 (22.9) 16 (40.6) 3-3/4 (9.5) 96 (243.8)
TUN, TEJ 3, 4 6, 8 14T5, 17, 24, 24HO 9 (22.9) 16 (40.6) 3-3/4 (9.5) 48 (121.9)
TUN, TEJ 3, 4 6, 8 21T5, 25, 36, 36HO, 39HO 9 (22.9) 16 (40.6) 3-3/4 (9.5) 72 (182.9)
TUN, TEJ 3, 4 6, 8 28T5, 32, 54T5HO 9 (22.9) 16 (40.6) 3-3/4 (9.5) 96 (243.8)
T2UN, T2EJ 2 4 28T5, 32, 54T5HO 9 (22.9) 16 (40.6) 3-3/4 (9.5) 96 (243.8)
T2UN, T2EJ 2 4 96T8, 96T8HO, 96HO, 96VHO 9 (22.9) 16 (40.6) 3-3/4 (9.5) 192 (487.7)
Drawings are for dimensional detail only and may not represent actual
mechanical conguration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
9
(22.9)
3-3/4
(9.5)
UN
12
(30.5)
3-3/4
(9.5)
EJ
Notes
1 For tandem double-length unit, add prex T. Example: TUN.
2 See Congurations table for lamp compatibility.
3 Available only with CSA option.
4 Consult factory for additional T12 and T12HO congurations.
5 Specify voltage.
6 Not available in Canada.
Heavy-Duty
UN
EJ
UN
EJ
PRODUCT INFORMATION

Summary of content (3 pages)