Installation Guide

STEP-BY-STEP GUIDE
Page 3
Trouble Shooting Guide
If this fi xture fails to operate properly, use the guide
below to diagnose and correct the problem.
 Verify that fi xture is wired properly.
 Verify that fi xture is grounded correctly.
 Verify that the line voltage at the fi xture is correct.
If further assistance is required, contact:
Technical Support at: (800) 748-5070
This LED module does not require service or new bulbs to change.
5. Place remote driver box thru the cut-out hole. If remote driver box
need to be attached, use provided keyhole fi ttings on the back of the box
to hang it using round head screw (not included). (Figure 5)
6. Pull the spring clip on the fi xture up and through the ceiling hole and
place module in the hole making sure the spring clips are holding securely.
(Figure 6)
7. Turn the power back on. If the module doesn’t illuminate within 5
seconds, turn power off, carefully remove the module and double check all
wiring and replace. (Figure 7)
WARNING:
 DO NOT PLACE YOUR HAND UNDERNEATH SPRING CLIP DUR
ING REMOVAL PROCESS. SNAPPING OF THE CLIPS CAN CAUSE
INJURIES TO THE HAND. (Figure 8)
 DO NOT USE ANY OTHER DRIVER EXCEPT LITHONIA LIGHTING
DRIVER THAT IS INCLUDED WITH THE FIXTURE.
 DO NOT CONNECT MULTIPLE MODULES TO ONE DRIVER.
 DO NOT OPEN THE MODULE AND SIDE PLATE OF THE REMOTE
DRIVER BOX - NO SERVICEABLE PARTS INSIDE.
Figure 6 / Figura 6 / Schéma 6
Figure 5 / Figura 5 / Schéma 5
ATTACH USING PROVIDED
KEYHOLE FITTINGS
(MOUNTING
OPTIONAL)
ROUND HEAD SCREWS
SIDE WALL
PULL UP
THROUGH
CEILING
HOLE
Figure 7 / Figura 7 / Schéma 7
Figure 8 / Figura 8 / Schéma 8
DO NOT
PLACE YOUR
HAND
DO NOT
PLACE YOUR
HAND
Note: Before beginning the installation, make sure all power is off,
shutting power off in breaker box to areas where downlights are to be
installed is recommended.
Required Tools (not included): Safety glasses and gloves.
1. Double check and measure the ceiling hole. Make sure it is the correct size
for outside rim of the luminaire to cover the hole while still allowing the back of
luminaire to sink in to the ceiling and springs to hold fi rmly.
 Remove existing retrofi t can if present or move it out of the way since it will
not be needed for installation.
 If new hole is to be cut, use provided hole template. Place
template over the desired location. Trace the outer ring with a pen or pencil (not
included). Cut the opening with a saw (not included). (Figure 1)
2. Open the cover of the remote driver box. Push and remove one of the
knockouts on the side plate.
 Locate power supply leads from remote driver box and connect to power
source using wago connectors (provided).
 Connect black wire to live wire, white wire to neutral wire, and green wire
with ground (as shown) and secure using wago connector. Close the cover of
the box. (Figure 2)
3. Connect the remote driver box to the light fi xture and tighten the nut con-
nector by hand. Arrow on the male and female parts of the connector between
the driver and fi xture cable should match. (Figure 3)
4. Use switch on the driver box (CCT option need to be selected before fi xture
installation) to select appropriate light color (warm, bright, or daylight option).
(Figure 4)
Figure 1 / Figura 1 / Schéma 1
THREAD
LOCK
Figure 4 / Figura 4 / Schéma 4
Figure 2 / Figura 2 / Schéma 2
Figure 3 /
Figura 3 /
Schéma 3
ACCESS
NEUTRAL WIRE
(FROM POWER SUPPLY)
GROUND WIRE
(FROM POWER SUPPLY)
LIVE WIRE
(FROM POWER SUPPLY)
CONNECT GROUND WIRE USING WAGO CONNECTOR
(ROMEX CABLE)
connector
connector
connector
NEUTRAL WIRE
GROUND WIRE
LIVE WIRE
NEUTRAL
WIRE
(WHITE)
GROUND
WIRE
(BARE COPPER /
GREEN)
LIVE
WIRE
(BLACK)
(FROM POWER SUPPLY)
(FROM DRIVER BOX)