Product Brochure

EFFLUENT PUMPS
HT-10EN HIGH TEMPERATURE - 1/2 HP
Boiler blow-down, euent wastewater removal, sump pits, transformer vaults
Rated for continuous duty use dewatering, water transfer, and euent wastewater removal applications
Energy-ecient PSC motor with thermal overload protection
Handles liquids up to 200 °F (93 °C)
Heavy duty epoxy coated cast iron housing
Solids handling up to 3/4" diameter
cCSAus listing
Volts Hz
Amps
Watts
Performance
(GPM @ Height in Feet)
Shut-O
(ft)
PSI
FLA Start 5' 10' 15' 20' 25'
115 60 10.5 21 900 75 65 60 40 20 30 13
Item No. Model HP Volts
Switch Type/
Operation
On Level O Level Cord Weight
511710
HT-10EN-CIA-FS
1/2
115
Integral Mechanical Float
9" - 14"
22.86 cm - 35.56 cm
2" - 4"
5 cm - 10.2 cm
15'
4.6 m
39 lbs
17.7 Kg
511610
HT-10EN-CIM
1/2 115 Manual
15'
4.6 m
38 lbs
17.24 Kg
FEATURES
SERIES SPECIFICATIONS
APPLICATIONS