Product Manual

Charger/Controller Electrical Ratings:
Input: 120 VAC, 3 Amp
Output (Maximum Charging Current):
Model 1210HF: 12 VDC, 10 Amps
Model 1212HF: 12VDC, 12 Amps
Use only with 12 VDC deep cycle battery rated 85 – 140Ah, lead-acid or AGM
s WARNING
!
WARNING
Do not use in explosive atmospheres. Do not handle Charger/Controller Unit with wet hands or when
standing on a wet or damp surface, or in water.
s WARNING
!
WARNING
To reduce risk of electric shock which can result in personal injury, death or major property damage if
ignored, be certain that the 115 VAC pump and the Charger/Controller Unit are connected to outlets protected by ground fault
circuit interrupters (GFCI). Comply with all national and local electrical and plumbing codes when installing this unit. Do not use
the same 115 VAC outlet for primary pump and Battery Charger/Controller Unit. Do not use extension cord.
s WARNING
!
WARNING
A spark near the battery may cause an explosion. Always unplug Charger/Controller Unit prior to
making connections to or disconnections from the battery. Take care to prevent accidental shorting across battery terminals
during handling. Do not leave battery uncovered. Attach or strap cover securely on battery box when completing installation.
s WARNING
!
CAUTION
The battery required to operate this unit contains acid and proper precautions must be taken when
handling. Refer to battery manufacturer’s safety guidelines. Failure to use proper personal protective equipment or electrical
caution can result in hazards that will or can cause personal injury or major property damage if ignored.
s WARNING
!
CAUTION
If a Carbon Monoxide (CO) sensor is installed near the battery backup system, battery, or Charger/
Controller Unit, nuisance or false alarms could result. CO detectors should be a minimum of 15 feet from the systems. Refer to
the manufacturer of CO detector for additional instructions or information.
s WARNING
!
CAUTION
The backup pump relies on a suciently charged battery to operate the pump. The charger is designed
to charge the battery and maintain charge level when the backup pump is not in use.
s
!
NOTICE: The Charger/Controller Unit emits an audible alarm when running the 12 VDC backup pump. An additional (not
supplied in this kit) audible high water alarm on the sump system is recommended in any installations where property damage
and/or personal injury might result from an inoperative sump system due to long term power outages, discharge line blockage,
or any other reason.
Charger/Controller Unit Installation
15